{"title":"Dissolved Oxygen Products","description":"Atlas Scientific dissolved oxygen probes, circuits, kits, and calibration solutions.","products":[{"product_id":"as-ezo-do","title":"Atlas Scientific EZO Dissolved Oxygen Circuit","description":"\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e\n\u003ctable style=\"height: 341px; width: 298px;\" border=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReads\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDissolved Oxygen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 − 100+ mg\/L\u003cbr\u003e0.1 − 400+ % saturation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/– 0.05 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResponse time\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 reading per sec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupported probes\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAny galvanic probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCalibration\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 or 2 point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemp. compensation\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSalinity compensation\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePressure compensation\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData protocol\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUART \u0026amp; I2C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDefault I2C address\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e97 (0x61)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating voltage\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.3V − 5V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv id=\"spec-text\"\u003e\u003cstrong\u003eData format\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv id=\"spec-text2\"\u003eASCII\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003e\u003cstrong\u003e\u003cstrong\u003eCircuit dimensions\u003c\/strong\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e13.97mm x 20.16mm (0.55\" x 0.79\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"spec-text\"\u003e\n\u003cdiv id=\"spec-text\"\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Atlas Scientific","offers":[{"title":"Default Title","offer_id":47400994996507,"sku":"AS-EZO-DO","price":6289.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0676\/3325\/0587\/products\/ezo-do.png?v=1701982529"},{"product_id":"as-chem-do","title":"Atlas Scientific Zero Dissolved Oxygen Calibration Solution","description":"\u003cdiv\u003e\n\u003cp\u003eAtlas Scientific Zero Dissolved Oxygen Calibration Solution is guaranteed not to have any oxygen in it.\u003c\/p\u003e\n\u003cp\u003eThis stuff is great for calibrating the low end of the Dissolved Oxygen scale or to confirm that your Dissolved Oxygen probe is working properly.\u003c\/p\u003e\n\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003cbr\u003e• 125mL\u003c\/div\u003e\n\u003cdiv\u003e• 0 mg\/mL Oxygen content\u003c\/div\u003e\n\u003cdiv id=\"copy-text\"\u003eThis product is used to confirm that Dissolved Oxygen Probe is working properly; it is used to calibrate the low end of the oxygen scale.\u003c\/div\u003e","brand":"Atlas Scientific","offers":[{"title":"Default Title","offer_id":47400995029275,"sku":"AS-CHEM-DO","price":2309.0,"currency_code":"INR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0676\/3325\/0587\/products\/img-2l9Xhl1TS1vpkw.jpg?v=1701982537"},{"product_id":"as-env-40-dox","title":"Atlas Scientific Mini Lab Grade Dissolved Oxygen Probe","description":"\u003cdiv class=\"elementor-toggle-item\"\u003e\n\u003cdiv id=\"elementor-tab-content-6841\" class=\"elementor-tab-content elementor-clearfix elementor-active\" data-tab=\"1\" role=\"region\" aria-labelledby=\"elementor-tab-title-6841\"\u003e\n\u003cheader\u003eDatasheets\u003c\/header\u003e\n\u003cul id=\"product-files-links\"\u003e\n\u003cli class=\"product-files-links-item\"\u003e\n\u003cimg loading=\"lazy\" width=\"60\" height=\"60\" src=\"https:\/\/atlas-scientific.com\/files\/do-white.png\" class=\"attachment-full size-full\" alt=\"\" decoding=\"async\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Mini_DO_probe.pdf\" target=\"_blank\"\u003eMini Lab Grade Dissolved Oxygen Probe Datasheet\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cheader\u003eDocuments\u003c\/header\u003e\n\u003cul id=\"product-files-links\"\u003e\n\u003cli class=\"product-files-links-item\"\u003e\n\u003cimg loading=\"lazy\" width=\"60\" height=\"60\" src=\"https:\/\/atlas-scientific.com\/files\/atlas-white.png\" class=\"attachment-full size-full\" alt=\"\" decoding=\"async\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/how-to-properly-cut-probe-cables.pdf\" target=\"_blank\"\u003eHow to properly cut your probe cable\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\n\u003cimg loading=\"lazy\" width=\"60\" height=\"60\" src=\"https:\/\/atlas-scientific.com\/files\/atlas-white.png\" class=\"attachment-full size-full\" alt=\"\" decoding=\"async\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/connecting-probes-into-a-pipe.pdf\" target=\"_blank\"\u003eConnecting probes into a pipe\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\n\u003cimg loading=\"lazy\" width=\"60\" height=\"60\" src=\"https:\/\/atlas-scientific.com\/files\/pdf-white.png\" class=\"attachment-full size-full\" alt=\"\" decoding=\"async\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/RoHS-Certificate.pdf\" target=\"_blank\"\u003eRoHS Certificate\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\n\u003cimg loading=\"lazy\" width=\"60\" height=\"60\" src=\"https:\/\/atlas-scientific.com\/files\/pdf-white.png\" class=\"attachment-full size-full\" alt=\"\" decoding=\"async\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/CE-Certificate.pdf\" target=\"_blank\"\u003eCE Certificate\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\n\u003cimg loading=\"lazy\" width=\"60\" height=\"60\" src=\"https:\/\/atlas-scientific.com\/files\/pdf-white.png\" class=\"attachment-full size-full\" alt=\"\" decoding=\"async\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/ELR-No-10-2011.pdf\" target=\"_blank\"\u003eEuropean legislation Regulation (EU) No 10\/2011\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\n\u003cimg loading=\"lazy\" width=\"60\" height=\"60\" src=\"https:\/\/atlas-scientific.com\/files\/pdf-white.png\" class=\"attachment-full size-full\" alt=\"\" decoding=\"async\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/ELR-No-1935-2004.pdf\" target=\"_blank\"\u003eEuropean legislation Regulation (EU) No 1935\/2004\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul id=\"product-files-links\"\u003e\u003c\/ul\u003e\n\u003cheader\u003e3D files\u003c\/header\u003e\n\u003cul id=\"product-files-links\"\u003e\n\u003cli class=\"product-files-links-item\"\u003e\n\u003cimg loading=\"lazy\" width=\"60\" height=\"60\" src=\"https:\/\/atlas-scientific.com\/files\/autodesk-white.png\" class=\"attachment-full size-full\" alt=\"\" decoding=\"async\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/ENV-20-DO.zip\" target=\"_blank\"\u003eENV-20-DOX 3D model (*step)\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cheader\u003eVideos\u003c\/header\u003e\n\u003cul id=\"product-files-links\"\u003e\n\u003cli class=\"product-files-links-item\"\u003e\n\u003cimg loading=\"lazy\" width=\"60\" height=\"60\" src=\"https:\/\/atlas-scientific.com\/files\/video-white.png\" class=\"attachment-full size-full\" alt=\"\" decoding=\"async\"\u003e\u003ca href=\"https:\/\/youtu.be\/1I1Sk9pt47c\" target=\"_blank\"\u003eDissolved Oxygen | Common Mistakes | Air Bubble\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\n\u003cimg loading=\"lazy\" width=\"60\" height=\"60\" src=\"https:\/\/atlas-scientific.com\/files\/video-white.png\" class=\"attachment-full size-full\" alt=\"\" decoding=\"async\"\u003e\u003ca href=\"https:\/\/youtu.be\/d9zkxkv55SE\" target=\"_blank\"\u003eDissolved Oxygen | Common Mistakes | Stagnant vs Moving Water\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\n\u003cimg loading=\"lazy\" width=\"60\" height=\"60\" src=\"https:\/\/atlas-scientific.com\/files\/video-white.png\" class=\"attachment-full size-full\" alt=\"\" decoding=\"async\"\u003e\u003ca href=\"https:\/\/youtu.be\/PiXnvrTnVjs\" target=\"_blank\"\u003eDissolved Oxygen | Common Mistakes | Damaged Membrane\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"elementor-toggle-item\"\u003e\n\u003cdiv id=\"elementor-tab-title-6842\" class=\"elementor-tab-title elementor-active\" data-tab=\"2\" role=\"button\" aria-controls=\"elementor-tab-content-6842\" aria-expanded=\"false\"\u003e\n\u003cspan class=\"elementor-toggle-icon elementor-toggle-icon-left\" aria-hidden=\"true\"\u003e\u003cspan class=\"elementor-toggle-icon-opened\"\u003e\u003ci class=\"elementor-toggle-icon-opened fas fa-caret-up\"\u003e\u003c\/i\u003e\u003c\/span\u003e\u003c\/span\u003e\u003ca class=\"elementor-toggle-title\" tabindex=\"0\"\u003eDescription\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"elementor-tab-content-6842\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"2\" role=\"region\" aria-labelledby=\"elementor-tab-title-6842\"\u003e\n\u003cp\u003e\u003cspan\u003eThe Atlas Scientific Mini Lab Grade Dissolved Oxygen probe is one of many unique products you will only find at Atlas Scientific. Designed for small spaces, this small probe gives you the same quality readings found in our lab-grade Dissolved Oxygen just smaller.  Because smaller probes use fewer precious metals, we can get the price lower. Keep in mind; smaller probes hold less electrolyte. Because of this, they need to be refilled more frequently than full-size or industrial probes.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"elementor-toggle-item\"\u003e\n\u003cdiv id=\"elementor-tab-title-6843\" class=\"elementor-tab-title elementor-active\" data-tab=\"3\" role=\"button\" aria-controls=\"elementor-tab-content-6843\" aria-expanded=\"false\"\u003e\n\u003cspan class=\"elementor-toggle-icon elementor-toggle-icon-left\" aria-hidden=\"true\"\u003e\u003cspan class=\"elementor-toggle-icon-opened\"\u003e\u003ci class=\"elementor-toggle-icon-opened fas fa-caret-up\"\u003e\u003c\/i\u003e\u003c\/span\u003e\u003c\/span\u003e\u003ca class=\"elementor-toggle-title\" tabindex=\"0\"\u003eSpecifications\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"elementor-tab-content-6843\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"3\" role=\"region\" aria-labelledby=\"elementor-tab-title-6843\"\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable class=\"product-specs-table\" border=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eReads\u003c\/td\u003e\n\u003ctd\u003eDissolved Oxygen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0 − 50 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e+\/– 0.2 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse time\u003c\/td\u003e\n\u003ctd\u003e~0.5 mg\/L\/per sec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature range °C\u003c\/td\u003e\n\u003ctd\u003e1 − 50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax pressure\u003c\/td\u003e\n\u003ctd\u003e689 kPa (100PSI)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax depth\u003c\/td\u003e\n\u003ctd\u003e70m (230 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector\u003c\/td\u003e\n\u003ctd\u003eMale SMA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable length\u003c\/td\u003e\n\u003ctd\u003e45cm (18″)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal temperature sensor\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTime before recalibration\u003c\/td\u003e\n\u003ctd\u003e~6 Months\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLife expectancy\u003c\/td\u003e\n\u003ctd\u003e2.5 Years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaintenance\u003c\/td\u003e\n\u003ctd\u003e~6 Months\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIncluded with Mini Dissolved Oxygen probe\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1x Syringe\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1x Replacement Membrane Cap\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1x 30ml bottle of Electrolyte Solution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Atlas Scientific","offers":[{"title":"Default Title","offer_id":47400995094811,"sku":"AS ENV-20-DOX","price":23309.0,"currency_code":"INR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0676\/3325\/0587\/files\/ENV-40-DOX-01.webp?v=1736448508"},{"product_id":"as-do-mem-r","title":"Atlas Scientific Dissolved Oxygen Lab Grade Membrane Replacement Kit","description":"\u003cp\u003eThis product is used to replace the PTFE sensing membrane for the Lab Grade Dissolved Oxygen probes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e• 2x Lab Grade Dissolved Oxygen probe replacement membranes.\u003c\/p\u003e\n\u003cp\u003eThis product is used to replace the PTFE sensing membrane for the Lab Grade Dissolved Oxygen probes.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"Atlas Scientific","offers":[{"title":"Default Title","offer_id":47400995750171,"sku":"AS-DO-MEM-R","price":8359.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0676\/3325\/0587\/products\/do-mem.png?v=1701982572"},{"product_id":"as-kit-104d","title":"Atlas Scientific Industrial Dissolved Oxygen Membrane Replacement Kit","description":"\u003cp\u003eThe silicone membrane used in the Atlas Scientific Industrial Dissolved Oxygen probe is tough, but nothing lasts forever. If your Dissolved Oxygen membrane starts cracking or it ruptures, don’t buy a new probe; just replace it with this kit.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable border=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e• 2x Industrial Dissolved Oxygen probe replacement membranes\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e• 2x Replacement O-rings\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e• 1x Membrane replacement tool\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e• 1x Bottle of replacement electrolyte\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Atlas Scientific","offers":[{"title":"Default Title","offer_id":47400995782939,"sku":"AS-Kit-104D","price":8859.0,"currency_code":"INR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0676\/3325\/0587\/products\/iDO-membrane-kit-01.jpg?v=1701982583"},{"product_id":"as-kit-103dx","title":"Atlas Scientific Dissolved Oxygen Kit","description":"\u003cdiv class=\"elementor-toggle-item\"\u003e\n\u003cdiv id=\"elementor-tab-content-6841\" class=\"elementor-tab-content elementor-clearfix elementor-active\" data-tab=\"1\"\u003eDatasheets\n\u003cul id=\"product-files-links\"\u003e\n\u003cli class=\"product-files-links-item\"\u003e\n\u003cimg class=\"attachment-full size-full\" src=\"https:\/\/atlas-scientific.com\/files\/do-white.png\" alt=\"\" width=\"60\" height=\"60\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/DO_EZO_Datasheet.pdf\" target=\"_blank\"\u003eEZO™ Dissolved Oxygen Circuit Datasheet\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\n\u003cimg class=\"attachment-full size-full\" src=\"https:\/\/atlas-scientific.com\/files\/do-white.png\" alt=\"\" width=\"60\" height=\"60\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/LG_DO_probe.pdf\" target=\"_blank\"\u003eLab Grade Dissolved Oxygen Probe Datasheet\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\n\u003cimg class=\"attachment-full size-full\" src=\"https:\/\/atlas-scientific.com\/files\/pwr-white.png\" alt=\"\" width=\"60\" height=\"60\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/electrically-isolated-ezo-carrier-board.pdf\" target=\"_blank\"\u003eElectrically Isolated EZO™ Carrier Board Datasheet\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\nDocuments\n\u003cul id=\"product-files-links\"\u003e\n\u003cli class=\"product-files-links-item\"\u003e\n\u003cimg class=\"attachment-full size-full\" src=\"https:\/\/atlas-scientific.com\/files\/wiring-diagram-white.png\" alt=\"\" width=\"60\" height=\"60\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/ezo-do-Wiringdiagram.pdf\" target=\"_blank\"\u003eWiring Diagram\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\n\u003cimg class=\"attachment-full size-full\" src=\"https:\/\/atlas-scientific.com\/files\/atlas-white.png\" alt=\"\" width=\"60\" height=\"60\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/connecting-probes-into-a-pipe.pdf\" target=\"_blank\"\u003eConnecting probes into a pipe\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\n\u003cimg class=\"attachment-full size-full\" src=\"https:\/\/atlas-scientific.com\/files\/atlas-white.png\" alt=\"\" width=\"60\" height=\"60\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/how-to-properly-cut-probe-cables.pdf\" target=\"_blank\"\u003eHow to properly cut your probe cable\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\n\u003cimg class=\"attachment-full size-full\" src=\"https:\/\/atlas-scientific.com\/files\/pdf-white.png\" alt=\"\" width=\"60\" height=\"60\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/RoHS-Certificate.pdf\" target=\"_blank\"\u003eRoHS Certificate\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\n\u003cimg class=\"attachment-full size-full\" src=\"https:\/\/atlas-scientific.com\/files\/pdf-white.png\" alt=\"\" width=\"60\" height=\"60\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/CE-Certificate.pdf\" target=\"_blank\"\u003eCE Certificate\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\n\u003cimg class=\"attachment-full size-full\" src=\"https:\/\/atlas-scientific.com\/files\/pdf-white.png\" alt=\"\" width=\"60\" height=\"60\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/csa-certificate.pdf\" target=\"_blank\"\u003eCSA Certificate\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\nVideos\n\u003cul id=\"product-files-links\"\u003e\n\u003cli class=\"product-files-links-item\"\u003e\n\u003cimg class=\"attachment-full size-full\" src=\"https:\/\/atlas-scientific.com\/files\/video-white.png\" alt=\"\" width=\"60\" height=\"60\"\u003e\u003ca href=\"https:\/\/youtu.be\/1I1Sk9pt47c\" target=\"_blank\"\u003eDissolved Oxygen | Common Mistakes | Air Bubble\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\n\u003cimg class=\"attachment-full size-full\" src=\"https:\/\/atlas-scientific.com\/files\/video-white.png\" alt=\"\" width=\"60\" height=\"60\"\u003e\u003ca href=\"https:\/\/youtu.be\/d9zkxkv55SE\" target=\"_blank\"\u003eDissolved Oxygen | Common Mistakes | Stagnant vs Moving Water\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\n\u003cimg class=\"attachment-full size-full\" src=\"https:\/\/atlas-scientific.com\/files\/video-white.png\" alt=\"\" width=\"60\" height=\"60\"\u003e\u003ca href=\"https:\/\/youtu.be\/PiXnvrTnVjs\" target=\"_blank\"\u003eDissolved Oxygen | Common Mistakes | Damaged Membrane\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\nDownloads\n\u003cul id=\"product-files-links\"\u003e\n\u003cli class=\"product-files-links-item\"\u003e\n\u003cimg class=\"attachment-full size-full\" src=\"https:\/\/atlas-scientific.com\/files\/download-black.png\" alt=\"\" width=\"60\" height=\"60\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/AtlasDesktop.zip\" target=\"_blank\"\u003eFREE Software - AtlasDesktop Monitoring Software\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\n\u003cimg class=\"attachment-full size-full\" src=\"https:\/\/atlas-scientific.com\/files\/pdf-white.png\" alt=\"\" width=\"60\" height=\"60\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Atlasdesktop-user-guide.pdf\" target=\"_blank\"\u003eAtlasDesktop Monitoring Software Users Guide\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\nTools\n\u003cul id=\"product-files-links\"\u003e\n\u003cli class=\"product-files-links-item\"\u003e\n\u003cimg class=\"attachment-full size-full\" src=\"https:\/\/atlas-scientific.com\/files\/atlas-white.png\" alt=\"\" width=\"60\" height=\"60\"\u003e\u003ca href=\"https:\/\/atlas-scientific.com\/dissolved-oxygen-calculator\" target=\"_blank\"\u003eDissolved Oxygen Calculator\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\nBasic Sample Code\n\u003cul id=\"product-files-links\"\u003e\n\u003cli class=\"product-files-links-item\"\u003e\n\u003cimg class=\"attachment-full size-full\" src=\"https:\/\/atlas-scientific.com\/files\/arduino-white.png\" alt=\"\" width=\"60\" height=\"60\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Arduino-Uno-DO-sample-code.pdf\" target=\"_blank\"\u003eArduino Uno Sample Code\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\n\u003cimg class=\"attachment-full size-full\" src=\"https:\/\/atlas-scientific.com\/files\/arduino-white.png\" alt=\"\" width=\"60\" height=\"60\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Arduino-Mega-Giga-DO-Sample-Code.pdf\" target=\"_blank\"\u003eArduino Mega \/ Giga Sample Code\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\n\u003cimg class=\"attachment-full size-full\" src=\"https:\/\/atlas-scientific.com\/files\/arduino-white.png\" alt=\"\" width=\"60\" height=\"60\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Ardunio-I2C-DO-sample-code.pdf\" target=\"_blank\"\u003eArduino I2C Sample Code\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\n\u003cimg class=\"attachment-full size-full\" src=\"https:\/\/atlas-scientific.com\/files\/raspberry-pi-white.png\" alt=\"\" width=\"60\" height=\"60\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/pi_sample_code.pdf\" target=\"_blank\"\u003eRaspberry Pi Sample Code (UART, I2C, USB)\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n3D files\n\u003cul id=\"product-files-links\"\u003e\n\u003cli class=\"product-files-links-item\"\u003e\n\u003cimg class=\"attachment-full size-full\" src=\"https:\/\/atlas-scientific.com\/files\/autodesk-white.png\" alt=\"\" width=\"60\" height=\"60\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/dissolved_oxygen-footprint.zip\" target=\"_blank\"\u003eDissolved Oxygen. CAD Footprint File (*.dxf)\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul id=\"product-files-links\"\u003e\u003c\/ul\u003e\nLibrary\n\u003cul id=\"product-files-links\"\u003e\n\u003cli class=\"product-files-links-item\"\u003e\n\u003cimg class=\"attachment-full size-full\" src=\"https:\/\/atlas-scientific.com\/files\/git-hub-black.png\" alt=\"\" width=\"60\" height=\"60\"\u003e\u003ca href=\"https:\/\/github.com\/Atlas-Scientific\/Ezo_uart_lib\" target=\"_blank\"\u003eEZO UART Library\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\n\u003cimg class=\"attachment-full size-full\" src=\"https:\/\/atlas-scientific.com\/files\/git-hub-black.png\" alt=\"\" width=\"60\" height=\"60\"\u003e\u003ca href=\"https:\/\/github.com\/Atlas-Scientific\/Ezo_I2c_lib\" target=\"_blank\"\u003eEZO I2C Library\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"elementor-toggle-item\"\u003e\n\u003cdiv id=\"elementor-tab-title-6842\" class=\"elementor-tab-title elementor-active\" data-tab=\"2\"\u003e\u003ca class=\"elementor-toggle-title\" tabindex=\"0\"\u003eDescription\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv id=\"elementor-tab-content-6842\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"2\"\u003e\n\u003cp\u003e\u003cspan\u003eIf you are new to electrochemical sensing, knowing what components you need can get confusing. Let us help you. The Atlas Scientific EZO-\u003c\/span\u003e\u003cspan\u003eDissolved Oxygen\u003c\/span\u003e\u003cspan\u003e Kit gives you everything you need to take high accuracy, interference-free readings. Once you become familiar with electrochemical sensing, it will be easy for you to streamline your design and buy only the components that work for you.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"elementor-toggle-item\"\u003e\n\u003cdiv id=\"elementor-tab-title-6843\" class=\"elementor-tab-title elementor-active\" data-tab=\"3\"\u003e\u003ca class=\"elementor-toggle-title\" tabindex=\"0\"\u003eSpecifications\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv id=\"elementor-tab-content-6843\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"3\"\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable class=\"product-specs-table mceItemTable\" border=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e• 1x EZO™ Dissolved Oxygen Circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e• 1x Lab Grade Dissolved Oxygen Probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e• 1x 30ml bottle of Electrolyte Solution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e• 3x 20ml Zero Dissolved Oxygen calibration solution pouches\u003cbr\u003e\u003cem\u003e(used to confirm that the D.O. probe is working properly)\u003c\/em\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e• 1x Electrically Isolated EZO™ Carrier Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e• 1x Syringe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarrier Board dimensions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e56.2mm x 32mm (2.2″ x 1.2″)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight: 25 grams\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Atlas Scientific","offers":[{"title":"Default Title","offer_id":47400995848475,"sku":"AS-KIT-103DX","price":46149.0,"currency_code":"INR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0676\/3325\/0587\/files\/dissolved-oxygen-kit-01.jpg?v=1779188890"},{"product_id":"as-chem-do-e","title":"Atlas Scientific Replacement Dissolved Oxygen Electrolyte Solution","description":"\u003cp\u003e\u003cspan\u003eAs a Dissolved Oxygen probe ages, its output signal starts to get weaker. Eventually, you will start to see that the readings are lower than normal. This usually means that it’s time to replace the probes electrolyte solution. Where could you possibly find Dissolved Oxygen Probe Electrolyte Solution? My friend, look no further. This electrolyte solution will work for any galvanic D.O. probe regardless of brand or manufacturer.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"product-specs-table\" border=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e• 50mL of Dissolved Oxygen Electrolyte Solution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e• 3mL syringe included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThis product is used to replace the electrolyte solution inside the dissolved oxygen probe. This solution can refill up to 25 dissolved oxygen probes.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Atlas Scientific","offers":[{"title":"Default Title","offer_id":47400995881243,"sku":"AS-CHEM-DO-E","price":2879.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0676\/3325\/0587\/products\/do-es.png?v=1701982605"},{"product_id":"as-grv-do","title":"Atlas Scientific Surveyor™ Analog Dissolved Oxygen Meter","description":"\u003cdiv class=\"elementor-toggle-item\"\u003e\n\u003cdiv id=\"elementor-tab-title-6841\" class=\"elementor-tab-title elementor-active\" data-tab=\"1\"\u003e\u003ca class=\"elementor-toggle-title\" tabindex=\"0\"\u003eDocuments \u0026amp; Downloads\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv id=\"elementor-tab-content-6841\" class=\"elementor-tab-content elementor-clearfix elementor-active\" data-tab=\"1\"\u003eDatasheets\n\u003cul id=\"product-files-links\"\u003e\n\u003cli class=\"product-files-links-item\"\u003e\n\u003cimg class=\"attachment-full size-full\" src=\"https:\/\/atlas-scientific.com\/files\/do-white.png\" alt=\"\" width=\"60\" height=\"60\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Surveyor-DO-datasheet.pdf\" target=\"_blank\"\u003eSurveyor™ Analog D.O. Meter Datasheet\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\nVideos\n\u003cul id=\"product-files-links\"\u003e\n\u003cli class=\"product-files-links-item\"\u003e\n\u003cimg class=\"attachment-full size-full\" src=\"https:\/\/atlas-scientific.com\/files\/video-white.png\" alt=\"\" width=\"60\" height=\"60\"\u003e\u003ca href=\"https:\/\/youtu.be\/1I1Sk9pt47c\" target=\"_blank\"\u003eDissolved Oxygen | Common Mistakes | Air Bubble\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\n\u003cimg class=\"attachment-full size-full\" src=\"https:\/\/atlas-scientific.com\/files\/video-white.png\" alt=\"\" width=\"60\" height=\"60\"\u003e\u003ca href=\"https:\/\/youtu.be\/d9zkxkv55SE\" target=\"_blank\"\u003eDissolved Oxygen | Common Mistakes | Stagnant vs Moving Water\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\n\u003cimg class=\"attachment-full size-full\" src=\"https:\/\/atlas-scientific.com\/files\/video-white.png\" alt=\"\" width=\"60\" height=\"60\"\u003e\u003ca href=\"https:\/\/youtu.be\/PiXnvrTnVjs\" target=\"_blank\"\u003eDissolved Oxygen | Common Mistakes | Damaged Membrane\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\nTools\n\u003cul id=\"product-files-links\"\u003e\n\u003cli class=\"product-files-links-item\"\u003e\n\u003cimg class=\"attachment-full size-full\" src=\"https:\/\/atlas-scientific.com\/files\/atlas-white.png\" alt=\"\" width=\"60\" height=\"60\"\u003e\u003ca href=\"https:\/\/atlas-scientific.com\/dissolved-oxygen-calculator\" target=\"_blank\"\u003eDissolved Oxygen Calculator\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\nBasic Sample Code\n\u003cul id=\"product-files-links\"\u003e\n\u003cli class=\"product-files-links-item\"\u003e\n\u003cimg class=\"attachment-full size-full\" src=\"https:\/\/atlas-scientific.com\/files\/arduino-white.png\" alt=\"\" width=\"60\" height=\"60\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/surveyor-DO-ardunio-code.pdf\" target=\"_blank\"\u003eArduino Sample Code\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul id=\"product-files-links\"\u003e\u003c\/ul\u003e\nCertificates\n\u003cul id=\"product-files-links\"\u003e\n\u003cli class=\"product-files-links-item\"\u003e\n\u003cimg class=\"attachment-full size-full\" src=\"https:\/\/atlas-scientific.com\/files\/pdf-white.png\" alt=\"\" width=\"60\" height=\"60\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/RoHS-Certificate.pdf\" target=\"_blank\"\u003eRoHS Certificate\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\n\u003cimg class=\"attachment-full size-full\" src=\"https:\/\/atlas-scientific.com\/files\/pdf-white.png\" alt=\"\" width=\"60\" height=\"60\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/CE-Certificate.pdf\" target=\"_blank\"\u003eCE Certificate\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n3D files\n\u003cul id=\"product-files-links\"\u003e\n\u003cli class=\"product-files-links-item\"\u003e\n\u003cimg class=\"attachment-full size-full\" src=\"https:\/\/atlas-scientific.com\/files\/autodesk-white.png\" alt=\"\" width=\"60\" height=\"60\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/DO-Gravity.zip\" target=\"_blank\"\u003eSurveyor™ Analog D.O. Meter 3D model (*step)\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"elementor-toggle-item\"\u003e\n\u003cdiv id=\"elementor-tab-title-6842\" class=\"elementor-tab-title elementor-active\" data-tab=\"2\"\u003e\u003ca class=\"elementor-toggle-title\" tabindex=\"0\"\u003eDescription\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv id=\"elementor-tab-content-6842\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"2\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cem\u003e(Previously known as the Gravity Dissolved Oxygen Meter )\u003c\/em\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eAlthough Dissolved Oxygen is a complex measurement, it doesn’t always have to be. Some applications only need to know the presence of oxygen in percent saturation. If you are looking for basic measurements that you can rely on, The Atlas Scientific Surveyor™ Dissolved Oxygen Meter is your solution. This device outputs an analog voltage from 10mV – 1,000mV and gives D.O. readings in percent saturation only.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"elementor-toggle-item\"\u003e\n\u003cdiv id=\"elementor-tab-title-6843\" class=\"elementor-tab-title elementor-active\" data-tab=\"3\"\u003e\u003ca class=\"elementor-toggle-title\" tabindex=\"0\"\u003eSpecifications\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv id=\"elementor-tab-content-6843\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"3\"\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable class=\"product-specs-table mceItemTable\" border=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eReads\u003c\/td\u003e\n\u003ctd\u003eDissolved Oxygen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0 − 700% saturation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e+\/– 2%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse time\u003c\/td\u003e\n\u003ctd\u003eContinuous analog output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported probes\u003c\/td\u003e\n\u003ctd\u003eAny galvanic probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003eOptional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemp. compensation\u003c\/td\u003e\n\u003ctd\u003eNo (unnecessary)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData protocol\u003c\/td\u003e\n\u003ctd\u003eAnalog ~0 − ~3,000mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurveyor™ dimensions\u003c\/td\u003e\n\u003ctd\u003e56.2mm x 32mm (2.2″ x 1.2″)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight:\u003c\/td\u003e\n\u003ctd\u003e15 grams\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThe Surveyor™ Analog Dissolved Oxygen Meter\u003cbr\u003ecomes with (4) standoffs and screws,\u003cbr\u003e(1) 3 pin jumper cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Atlas Scientific","offers":[{"title":"Default Title","offer_id":47401003483419,"sku":"AS SRV-DO","price":2329.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0676\/3325\/0587\/products\/img-5JjEAghb9hJExz.jpg?v=1701983668"},{"product_id":"as-do-oem","title":"Atlas Scientific Dissolved Oxygen OEM Circuit","description":"\u003cp\u003eWhen mass-producing a machine that has dissolved oxygen sensing capabilities, you need low cost, pick, and placeable components. With a small 12 x 11mm footprint, the Atlas Scientific OEM DO Circuit gives you full D.O. sensing capabilities without consuming costly board space. At just $9 in quantity, your machine now has all the capabilities found in a $500 D.O. meter.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"elementor-accordion-item\"\u003e\n\u003cdiv id=\"elementor-tab-content-1262\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"2\"\u003e\n\u003ctable class=\"product-specs-table\" border=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eReads\u003c\/td\u003e\n\u003ctd\u003eDissolved Oxygen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0.01 − 100+ mg\/L\u003cbr\u003e0.1 − 400+ % saturation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e+\/– 0.05 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse time\u003c\/td\u003e\n\u003ctd\u003e1 reading every 420ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported probes\u003c\/td\u003e\n\u003ctd\u003eAny galvanic probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003e1 or 2 point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature, salinity and pressure compensation\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData protocol\u003c\/td\u003e\n\u003ctd\u003eSMBus\/I2C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDefault I2C address\u003c\/td\u003e\n\u003ctd\u003e0x67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating voltage\u003c\/td\u003e\n\u003ctd\u003e3.3V − 5V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData format\u003c\/td\u003e\n\u003ctd\u003eASCII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCircuit dimensions\u003c\/td\u003e\n\u003ctd\u003e12mm x 11mm (0.47″ x 0.43″)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight:\u003c\/td\u003e\n\u003ctd\u003e0.51 grams\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Atlas Scientific","offers":[{"title":"Default Title","offer_id":47401003581723,"sku":"AS-DO-OEM","price":6289.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0676\/3325\/0587\/products\/img-19ad31KUEwgnFP.jpg?v=1701983686"},{"product_id":"as-env-20-dox","title":"Atlas Scientific Lab Grade Dissolved Oxygen Probe","description":"\u003cdiv class=\"elementor-toggle-item\"\u003e\n\u003cdiv id=\"elementor-tab-content-6841\" class=\"elementor-tab-content elementor-clearfix elementor-active\" data-tab=\"1\"\u003eDatasheets\n\u003cul id=\"product-files-links\"\u003e\n\u003cli class=\"product-files-links-item\"\u003e\n\u003cimg class=\"attachment-full size-full\" src=\"https:\/\/atlas-scientific.com\/files\/do-white.png\" alt=\"\" width=\"60\" height=\"60\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/LG_DO_probe.pdf\" target=\"_blank\"\u003eLab Grade Dissolved Oxygen Probe Datasheet\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\n\u003cimg class=\"attachment-full size-full\" src=\"https:\/\/atlas-scientific.com\/files\/do-white.png\" alt=\"\" width=\"60\" height=\"60\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/l-do-probe.pdf\" target=\"_blank\"\u003eLEGACY Lab Grade Dissolved Oxygen Probe Datasheet\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\nDocuments\n\u003cul id=\"product-files-links\"\u003e\n\u003cli class=\"product-files-links-item\"\u003e\n\u003cimg class=\"attachment-full size-full\" src=\"https:\/\/atlas-scientific.com\/files\/atlas-white.png\" alt=\"\" width=\"60\" height=\"60\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/how-to-properly-cut-probe-cables.pdf\" target=\"_blank\"\u003eHow to properly cut your probe cable\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\n\u003cimg class=\"attachment-full size-full\" src=\"https:\/\/atlas-scientific.com\/files\/atlas-white.png\" alt=\"\" width=\"60\" height=\"60\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/connecting-probes-into-a-pipe.pdf\" target=\"_blank\"\u003eConnecting probes into a pipe\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\n\u003cimg class=\"attachment-full size-full\" src=\"https:\/\/atlas-scientific.com\/files\/pdf-white.png\" alt=\"\" width=\"60\" height=\"60\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/RoHS-Certificate.pdf\" target=\"_blank\"\u003eRoHS Certificate\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\n\u003cimg class=\"attachment-full size-full\" src=\"https:\/\/atlas-scientific.com\/files\/pdf-white.png\" alt=\"\" width=\"60\" height=\"60\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/CE-Certificate.pdf\" target=\"_blank\"\u003eCE Certificate\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\n\u003cimg class=\"attachment-full size-full\" src=\"https:\/\/atlas-scientific.com\/files\/pdf-white.png\" alt=\"\" width=\"60\" height=\"60\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/ELR-No-10-2011.pdf\" target=\"_blank\"\u003eEuropean legislation Regulation (EU) No 10\/2011\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\n\u003cimg class=\"attachment-full size-full\" src=\"https:\/\/atlas-scientific.com\/files\/pdf-white.png\" alt=\"\" width=\"60\" height=\"60\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/ELR-No-1935-2004.pdf\" target=\"_blank\"\u003eEuropean legislation Regulation (EU) No 1935\/2004\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul id=\"product-files-links\"\u003e\u003c\/ul\u003e\n3D files\n\u003cul id=\"product-files-links\"\u003e\n\u003cli class=\"product-files-links-item\"\u003e\n\u003cimg class=\"attachment-full size-full\" src=\"https:\/\/atlas-scientific.com\/files\/autodesk-white.png\" alt=\"\" width=\"60\" height=\"60\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/ENV-40-DOX.zip\" target=\"_blank\"\u003eENV-40-DOX 3D model (*step)\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\nVideos\n\u003cul id=\"product-files-links\"\u003e\n\u003cli class=\"product-files-links-item\"\u003e\n\u003cimg class=\"attachment-full size-full\" src=\"https:\/\/atlas-scientific.com\/files\/video-white.png\" alt=\"\" width=\"60\" height=\"60\"\u003e\u003ca href=\"https:\/\/youtu.be\/1I1Sk9pt47c\" target=\"_blank\"\u003eDissolved Oxygen | Common Mistakes | Air Bubble\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\n\u003cimg class=\"attachment-full size-full\" src=\"https:\/\/atlas-scientific.com\/files\/video-white.png\" alt=\"\" width=\"60\" height=\"60\"\u003e\u003ca href=\"https:\/\/youtu.be\/d9zkxkv55SE\" target=\"_blank\"\u003eDissolved Oxygen | Common Mistakes | Stagnant vs Moving Water\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\n\u003cimg class=\"attachment-full size-full\" src=\"https:\/\/atlas-scientific.com\/files\/video-white.png\" alt=\"\" width=\"60\" height=\"60\"\u003e\u003ca href=\"https:\/\/youtu.be\/PiXnvrTnVjs\" target=\"_blank\"\u003eDissolved Oxygen | Common Mistakes | Damaged Membrane\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"elementor-toggle-item\"\u003e\n\u003cdiv id=\"elementor-tab-title-6842\" class=\"elementor-tab-title elementor-active\" data-tab=\"2\"\u003e\u003ca class=\"elementor-toggle-title\" tabindex=\"0\"\u003eDescription\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv id=\"elementor-tab-content-6842\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"2\"\u003e\n\u003cp\u003e\u003cspan\u003eThe Atlas Scientific Lab Grade Dissolved Oxygen probe is a durable little probe that can work in almost any environment. From basic laboratory work to remote fish farm monitoring, this probe has been installed in thousands of different machines worldwide.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"elementor-toggle-item\"\u003e\n\u003cdiv id=\"elementor-tab-title-6843\" class=\"elementor-tab-title elementor-active\" data-tab=\"3\"\u003e\u003ca class=\"elementor-toggle-title\" tabindex=\"0\"\u003eSpecifications\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv id=\"elementor-tab-content-6843\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"3\"\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable class=\"product-specs-table mceItemTable\" border=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eReads\u003c\/td\u003e\n\u003ctd\u003eDissolved Oxygen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0 − 100 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e+\/– 0.05 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse time\u003c\/td\u003e\n\u003ctd\u003e~0.3 mg\/L\/per sec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature range °C\u003c\/td\u003e\n\u003ctd\u003e1 − 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax pressure\u003c\/td\u003e\n\u003ctd\u003e3,447 kPa (500PSI)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax depth\u003c\/td\u003e\n\u003ctd\u003e352m (1,157 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector\u003c\/td\u003e\n\u003ctd\u003eMale SMA \/ Male BNC \u003cem\u003e\u003cspan\u003e(optional)\u003c\/span\u003e\u003c\/em\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable length\u003c\/td\u003e\n\u003ctd\u003e1 meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal temperature sensor\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTime before recalibration\u003c\/td\u003e\n\u003ctd\u003e~1 Year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLife expectancy\u003c\/td\u003e\n\u003ctd\u003e~4 Years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaintenance\u003c\/td\u003e\n\u003ctd\u003e~18 Months\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIncluded with Lab Grade Dissolved Oxygen probe\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1x Syringe\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1x 30ml bottle of Electrolyte Solution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Atlas Scientific","offers":[{"title":"Default Title","offer_id":47401003614491,"sku":"AS ENV-40-DOX","price":30309.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0676\/3325\/0587\/files\/ENV-40-DOX-01a.webp?v=1739875064"},{"product_id":"as-kit-105dx","title":"Surveyor™ Analog Dissolved Oxygen Kit","description":"\u003cp\u003e\u003cspan\u003eThe Atlas Scientific Gravity Dissolved Oxygen Kit is a low-cost solution for engineers who are looking for a simple monitoring solution with a basic analog output. \u003cstrong\u003eThis kit Reads Dissolved Oxygen in Percent Saturation only.it can not read MG\/L.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"product-specs-table\" border=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e• 1 Gravity™ Analog Dissolved Oxygen Meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e• 1 Mini Lab Grade Dissolved Oxygen Probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e• 1 30ml bottle of Electrolyte Solution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e• 1 Replacement Membrane Cap\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e• 1 Syringe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGravity™ dimensions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e56.2mm x 32mm (2.2″ x 1.2″)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight: 15 grams\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Atlas Scientific","offers":[{"title":"Default Title","offer_id":47401003680027,"sku":"AS-Kit-105DX","price":25059.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0676\/3325\/0587\/products\/img-1uro3ESXQfbex2.jpg?v=1701983715"},{"product_id":"as-env-50-do","title":"Atlas Scientific Industrial Dissolved Oxygen Probe","description":"\u003cp\u003eWhen you need long term readings from a probe that’s almost impossible to break, the Atlas Scientific Industrial Dissolved Oxygen probe is what you need. The probe holds a lot of electrolyte so it will last for a long time before needing reconditioning. The built-in PT-1000 temperature sensor and threaded body reduces the need for excess parts and makes it easy to install in a pipe.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\" cke_show_border\" border=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eReads\u003c\/td\u003e\n\u003ctd\u003eDissolved Oxygen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0 − 100 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e+\/– 0.05 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse time\u003c\/td\u003e\n\u003ctd\u003e~0.1 mg\/L\/per sec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature range °C\u003c\/td\u003e\n\u003ctd\u003e1 − 99 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax pressure\u003c\/td\u003e\n\u003ctd\u003e300 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax depth\u003c\/td\u003e\n\u003ctd\u003e212m (694 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector\u003c\/td\u003e\n\u003ctd\u003eTinned leads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable length\u003c\/td\u003e\n\u003ctd\u003e3 Meters (10′)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal temperature sensor\u003c\/td\u003e\n\u003ctd\u003eYes (PT-1000)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTime before recalibration\u003c\/td\u003e\n\u003ctd\u003e~1 Year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLife expectancy\u003c\/td\u003e\n\u003ctd\u003e~4 Years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaintenance\u003c\/td\u003e\n\u003ctd\u003e~18 Months\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRelated Documents\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul id=\"product-files-links\"\u003e\n\u003cli\u003e\n\u003cimg title=\"EZO™ Dissolved Oxygen Circuit\" src=\"https:\/\/atlas-scientific.com\/files\/do-white.png\" alt=\"EZO™ Dissolved Oxygen Circuit\" data-cke-saved-src=\"https:\/\/atlas-scientific.com\/files\/do-white.png\"\u003e \u003ca href=\"https:\/\/atlas-scientific.com\/files\/Industrial-DO-probe.pdf\" target=\"_blank\" data-cke-saved-href=\"https:\/\/atlas-scientific.com\/files\/Industrial-DO-probe.pdf\"\u003eIndustrial Dissolved Oxygen Datasheet\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cimg title=\"Mini Lab Grade Dissolved Oxygen Probe\" src=\"https:\/\/atlas-scientific.com\/files\/atlas-white.png\" alt=\"Mini Lab Grade Dissolved Oxygen Probe\" data-cke-saved-src=\"https:\/\/atlas-scientific.com\/files\/atlas-white.png\"\u003e \u003ca href=\"https:\/\/atlas-scientific.com\/files\/connecting-probes-into-a-pipe.pdf\" target=\"_blank\" data-cke-saved-href=\"https:\/\/atlas-scientific.com\/files\/connecting-probes-into-a-pipe.pdf\"\u003eConnecting probes into a pipe\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cimg title=\"EZO™ Dissolved Oxygen Circuit\" src=\"https:\/\/atlas-scientific.com\/files\/pdf-white.png\" alt=\"EZO™ Dissolved Oxygen Circuit\" data-cke-saved-src=\"https:\/\/atlas-scientific.com\/files\/pdf-white.png\"\u003e \u003ca href=\"https:\/\/atlas-scientific.com\/files\/RoHS-Certificate.pdf\" target=\"_blank\" data-cke-saved-href=\"https:\/\/atlas-scientific.com\/files\/RoHS-Certificate.pdf\"\u003eRoHS Certificate\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cimg title=\"EZO™ Dissolved Oxygen Circuit\" src=\"https:\/\/atlas-scientific.com\/files\/pdf-white.png\" alt=\"EZO™ Dissolved Oxygen Circuit\" data-cke-saved-src=\"https:\/\/atlas-scientific.com\/files\/pdf-white.png\"\u003e \u003ca href=\"https:\/\/atlas-scientific.com\/files\/CE-Certificate.pdf\" target=\"_blank\" data-cke-saved-href=\"https:\/\/atlas-scientific.com\/files\/CE-Certificate.pdf\"\u003eCE Certificate\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cimg title=\"EZO™ pH Circuit\" src=\"https:\/\/atlas-scientific.com\/files\/autocad-black.png\" alt=\"EZO™ pH Circuit\" data-cke-saved-src=\"https:\/\/atlas-scientific.com\/files\/autocad-black.png\"\u003e \u003ca href=\"https:\/\/atlas-scientific.com\/files\/ENV-50-DO.zip\" target=\"_blank\" data-cke-saved-href=\"https:\/\/atlas-scientific.com\/files\/ENV-50-DO.zip\"\u003eENV-50-DO 3D model (*step)\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Atlas Scientific","offers":[{"title":"Default Title","offer_id":47401004040475,"sku":"AS-ENV-50-DO","price":38499.0,"currency_code":"INR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0676\/3325\/0587\/products\/IMG-2LsSqS7lwSaifs.jpg?v=1701983873"},{"product_id":"as-kit-106d","title":"Atlas Scientific Industrial Dissolved Oxygen Kit","description":"\u003cp\u003eAre you working with a PLC and aren’t sure what parts are right for you? Let us help you. This is the Atlas Scientific industrial Dissolved Oxygen kit. It comes with everything you need to take high accuracy, interference-free readings with a PLC. The industrial strength Dissolved Oxygen probe is ready for the job, whatever it may be. The DIN rail mount and wide operating voltage makes it easy to install. The 4-20mA data output and display makes it easy to read. And the simple calibration protocol gets you up and running in no time.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable border=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e1 IXIAN™ Dissolved Oxygen Transmitter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1 Industrial Dissolved Oxygen Probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1 125mL (8oz) bottle of Zero Dissolved Oxygen Calibration Solution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Max Pressure: 100 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Cable length: 3 Meters (10′)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Weight: 396 grams\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Atlas Scientific","offers":[{"title":"Default Title","offer_id":47401004204315,"sku":"AS-KIT-106D","price":72039.0,"currency_code":"INR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0676\/3325\/0587\/products\/img-2jF567ADVXrFor.jpg?v=1701983899"},{"product_id":"as-ixian-do","title":"Atlas Scientific IXIAN Dissolved Oxygen Transmitter","description":"\u003cp\u003eFor some reason buying a dissolved oxygen transmitter involves clicking the “request quote” box. I think we all know what that mean$. Atlas Scientific isn’t interested in customizing the price based on who you are. We know who you are; you’re an engineer building a machine. Like other Atlas Scientific products, this dissolved oxygen transmitter gives you a simple solution to a complex measurement. Hook it up, calibrate the probe, get the readings and move on with your life. Simple, the way it should be.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable border=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eReads\u003c\/td\u003e\n\u003ctd\u003eDissolved Oxygen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0.00 mg\/L to 32.00 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e+\/– 0.2 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003e1 or 2 point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported probes\u003c\/td\u003e\n\u003ctd\u003eAny type \/ brand of galvanic D.O. probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto temp compensation\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSea water compensation\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMount\u003c\/td\u003e\n\u003ctd\u003e35mm Din rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput\u003c\/td\u003e\n\u003ctd\u003e4 − 20mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating voltage\u003c\/td\u003e\n\u003ctd\u003e9VDC − 36VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrically isolated\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eDoccument:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul id=\"product-files-links\"\u003e\n\u003cli\u003e \u003ca href=\"https:\/\/files.atlas-scientific.com\/DO_transmitter.pdf\" target=\"_blank\"\u003eIXIAN™ Dissolved Oxygen Transmitter Datasheet\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cimg title=\"EZO™ Dissolved Oxygen Circuit\" src=\"https:\/\/atlas-scientific.com\/files\/pdf-white.png\" alt=\"EZO™ Dissolved Oxygen Circuit\"\u003e \u003ca href=\"https:\/\/files.atlas-scientific.com\/RoHS-Certificate.pdf\" target=\"_blank\"\u003eRoHS Certificate\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cimg title=\"EZO™ Dissolved Oxygen Circuit\" src=\"https:\/\/atlas-scientific.com\/files\/pdf-white.png\" alt=\"EZO™ Dissolved Oxygen Circuit\"\u003e \u003ca href=\"https:\/\/files.atlas-scientific.com\/CE-Certificate.pdf\" target=\"_blank\"\u003eCE Certificate\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Atlas Scientific","offers":[{"title":"Default Title","offer_id":47401004335387,"sku":"AS-IXIAN-DO","price":27979.0,"currency_code":"INR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0676\/3325\/0587\/products\/img-12vrz1TyHU4qQ8.jpg?v=1701983923"},{"product_id":"as-do-mem-rm","title":"Dissolved Oxygen Mini Lab Grade Membrane Replacement Kit","description":"\u003cp\u003e\u003cspan\u003eThis product is used to replace the PTFE sensing membrane for the Mini Lab Grade Dissolved Oxygen probes.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"product-specs-table\" border=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e Two Mini Lab Grade Dissolved Oxygen probe replacement membranes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThis product is used to replace the PTFE sensing membrane for the Mini Lab Grade Dissolved Oxygen probes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Atlas Scientific","offers":[{"title":"Default Title","offer_id":47401005842715,"sku":"AS-DO-MEM-RM","price":6759.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0676\/3325\/0587\/products\/Mini-DO-lab-grade-probe-membrane-replacement-01.jpg?v=1701984092"},{"product_id":"asdop","title":"Atlas Scientific Zero Dissolved Oxygen Calibration Solution Pouch","description":"\u003cp\u003eAtlas Scientific Zero Dissolved Oxygen Calibration Solution is guaranteed not to have any oxygen in it.\u003c\/p\u003e\n\u003cp\u003eThis stuff is great for calibrating the low end of the Dissolved Oxygen scale or to confirm that your Dissolved Oxygen probe is working properly.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification: \u003c\/strong\u003e• 20ml each pouch\u003c\/p\u003e\n\u003cp\u003e • 0 mg\/mL Oxygen content\u003c\/p\u003e\n\u003cp\u003eThis product is used to confirm that Dissolved Oxygen Probe is working properly; it is used to calibrate the low end of the oxygen scale.\u003c\/p\u003e","brand":"Atlas Scientific","offers":[{"title":"Default Title","offer_id":47401008759067,"sku":"ASDOP","price":909.0,"currency_code":"INR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0676\/3325\/0587\/products\/DO-pouch-01.jpg?v=1701984710"},{"product_id":"asdop-3","title":"Atlas Scientific Zero Dissolved Oxygen Calibration Set (3 pouches)","description":"\u003cp\u003eAtlas Scientific Zero Dissolved Oxygen Calibration Solution is guaranteed not to have any oxygen in it.\u003c\/p\u003e\n\u003cp\u003eThis stuff is great for calibrating the low end of the Dissolved Oxygen scale or to confirm that your Dissolved Oxygen probe is working properly.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications: \u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable border=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e• 3x Zero Dissolved Oxygen Calibration Solution pouches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e• 20ml each pouch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e• 0 mg\/mL Oxygen content\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThis product is used to confirm that Dissolved Oxygen Probe is working properly; it is used to calibrate the low end of the oxygen scale.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDocuments:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul id=\"product-files-links\"\u003e\n\u003cli\u003e\n\u003cimg src=\"https:\/\/atlas-scientific.com\/files\/pdf-white.png\" alt=\"\"\u003e \u003ca href=\"https:\/\/files.atlas-scientific.com\/Dissolved-Oxygen-Solution-SDS.pdf\" target=\"_blank\"\u003eDissolved Oxygen Calibration Solution SDS\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Atlas Scientific","offers":[{"title":"Default Title","offer_id":47401008791835,"sku":"ASDOP-3","price":2679.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0676\/3325\/0587\/products\/Zero-DO-calibration-solution-pouches-01.jpg?v=1701984728"},{"product_id":"ezo-complete-dissolved-oxygen™","title":"EZO Complete-Dissolved Oxygen™","description":"\u003cdiv class=\"elementor-toggle-item\"\u003e\n\u003cdiv id=\"elementor-tab-content-6842\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"2\"\u003e\n\u003cp\u003eThe EZO-Complete USB Dissolved Oxygen meter makes building a custom monitoring system easy. Simply connect the EZO-Complete to a PC and install the free Atlas Desktop software. Connect multiple EZO-Complete Dissolved Oxygen modules to read D.O. from multiple locations. Embedded systems engineers can use EZO-Complete Dissolved Oxygen with any USB-enabled microcontroller. EZO-Complete will create a virtual comport and is controlled using simple serial strings.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"elementor-toggle-item\"\u003e\n\u003cdiv id=\"elementor-tab-title-6843\" class=\"elementor-tab-title elementor-active\" data-tab=\"3\"\u003e\u003cstrong\u003e\u003ca class=\"elementor-toggle-title\" tabindex=\"0\"\u003eSpecifications:\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv id=\"elementor-tab-content-6843\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"3\"\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable class=\"product-specs-table mceItemTable\" border=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eReads\u003c\/td\u003e\n\u003ctd\u003eDissolved Oxygen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0.00 − 100+ mg\/L\u003cbr\u003e0 − 350% saturation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e.01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e+\/– 0.05 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse time\u003c\/td\u003e\n\u003ctd\u003e1 reading per sec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported probes\u003c\/td\u003e\n\u003ctd\u003eAny galvanic probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003e1 or 2 point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemp. compensation\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity compensation\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure compensation\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternational standard\u003c\/td\u003e\n\u003ctd\u003eISO 5814 compliant\u003cbr\u003e(determination of dissolved oxygen)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e75.7mm x 54.3mm (2.9″ x 2.1″)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e~54 grams\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData protocol\u003c\/td\u003e\n\u003ctd\u003eSerial strings through FTDI virtual comport\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData format\u003c\/td\u003e\n\u003ctd\u003eASCII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating voltage\u003c\/td\u003e\n\u003ctd\u003e5V USB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca class=\"elementor-toggle-title\" tabindex=\"0\"\u003eDocuments \u0026amp; Downloads:\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDatasheet for Engineers\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul id=\"product-files-links\"\u003e\n\u003cli class=\"product-files-links-item\"\u003e\n\u003cimg class=\"attachment-full size-full\" src=\"https:\/\/atlas-scientific.com\/files\/do-white.png\" alt=\"\" width=\"60\" height=\"60\" data-mce-src=\"https:\/\/atlas-scientific.com\/files\/do-white.png\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/EZO-DO-complete-datasheet.pdf\" target=\"_blank\" data-mce-href=\"https:\/\/files.atlas-scientific.com\/EZO-DO-complete-datasheet.pdf\"\u003eEZO Complete-DO Datasheet for Engineers\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eInstructions for use with Atlas Desktop\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul id=\"product-files-links\"\u003e\n\u003cli class=\"product-files-links-item\"\u003e\n\u003cimg class=\"attachment-full size-full\" src=\"https:\/\/atlas-scientific.com\/files\/do-white.png\" alt=\"\" width=\"60\" height=\"60\" data-mce-src=\"https:\/\/atlas-scientific.com\/files\/do-white.png\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/EZO-DO-complete-users-guide.pdf\" target=\"_blank\" data-mce-href=\"https:\/\/files.atlas-scientific.com\/EZO-DO-complete-users-guide.pdf\"\u003eEZO Complete-DO Users Guide\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDownloads\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul id=\"product-files-links\"\u003e\n\u003cli class=\"product-files-links-item\"\u003e\n\u003cimg class=\"attachment-full size-full\" src=\"https:\/\/atlas-scientific.com\/files\/download-black.png\" alt=\"\" width=\"60\" height=\"60\" data-mce-src=\"https:\/\/atlas-scientific.com\/files\/download-black.png\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/AtlasDesktop.zip\" target=\"_blank\" data-mce-href=\"https:\/\/files.atlas-scientific.com\/AtlasDesktop.zip\"\u003eFREE Software - AtlasDesktop Monitoring Software\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\n\u003cimg class=\"attachment-full size-full\" src=\"https:\/\/atlas-scientific.com\/files\/pdf-white.png\" alt=\"\" width=\"60\" height=\"60\" data-mce-src=\"https:\/\/atlas-scientific.com\/files\/pdf-white.png\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Atlasdesktop-user-guide.pdf\" target=\"_blank\" data-mce-href=\"https:\/\/files.atlas-scientific.com\/Atlasdesktop-user-guide.pdf\"\u003eAtlasDesktop Monitoring Software Users Guide\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eVideos\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul id=\"product-files-links\"\u003e\n\u003cli class=\"product-files-links-item\"\u003e\n\u003cimg class=\"attachment-full size-full\" src=\"https:\/\/atlas-scientific.com\/files\/video-white.png\" alt=\"\" width=\"60\" height=\"60\" data-mce-src=\"https:\/\/atlas-scientific.com\/files\/video-white.png\"\u003e\u003ca href=\"https:\/\/youtu.be\/1I1Sk9pt47c\" target=\"_blank\" data-mce-href=\"https:\/\/youtu.be\/1I1Sk9pt47c\"\u003eDissolved Oxygen | Common Mistakes | Air Bubble\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\n\u003cimg class=\"attachment-full size-full\" src=\"https:\/\/atlas-scientific.com\/files\/video-white.png\" alt=\"\" width=\"60\" height=\"60\" data-mce-src=\"https:\/\/atlas-scientific.com\/files\/video-white.png\"\u003e\u003ca href=\"https:\/\/youtu.be\/d9zkxkv55SE\" target=\"_blank\" data-mce-href=\"https:\/\/youtu.be\/d9zkxkv55SE\"\u003eDissolved Oxygen | Common Mistakes | Stagnant vs Moving Water\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\n\u003cimg class=\"attachment-full size-full\" src=\"https:\/\/atlas-scientific.com\/files\/video-white.png\" alt=\"\" width=\"60\" height=\"60\" data-mce-src=\"https:\/\/atlas-scientific.com\/files\/video-white.png\"\u003e\u003ca href=\"https:\/\/youtu.be\/PiXnvrTnVjs\" target=\"_blank\" data-mce-href=\"https:\/\/youtu.be\/PiXnvrTnVjs\"\u003eDissolved Oxygen | Common Mistakes | Damaged Membrane\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTools\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul id=\"product-files-links\"\u003e\n\u003cli class=\"product-files-links-item\"\u003e\n\u003cimg class=\"attachment-full size-full\" src=\"https:\/\/atlas-scientific.com\/files\/atlas-white.png\" alt=\"\" width=\"60\" height=\"60\" data-mce-src=\"https:\/\/atlas-scientific.com\/files\/atlas-white.png\"\u003e\u003ca href=\"https:\/\/atlas-scientific.com\/dissolved-oxygen-calculator\" target=\"_blank\" data-mce-href=\"https:\/\/atlas-scientific.com\/dissolved-oxygen-calculator\"\u003eDissolved Oxygen Calculator\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCertificates\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul id=\"product-files-links\"\u003e\n\u003cli class=\"product-files-links-item\"\u003e\n\u003cimg class=\"attachment-full size-full\" src=\"https:\/\/atlas-scientific.com\/files\/pdf-white.png\" alt=\"\" width=\"60\" height=\"60\" data-mce-src=\"https:\/\/atlas-scientific.com\/files\/pdf-white.png\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/RoHS-Certificate.pdf\" target=\"_blank\" data-mce-href=\"https:\/\/files.atlas-scientific.com\/RoHS-Certificate.pdf\"\u003eRoHS Certificate\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\n\u003cimg class=\"attachment-full size-full\" src=\"https:\/\/atlas-scientific.com\/files\/pdf-white.png\" alt=\"\" width=\"60\" height=\"60\" data-mce-src=\"https:\/\/atlas-scientific.com\/files\/pdf-white.png\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/CE-Certificate.pdf\" target=\"_blank\" data-mce-href=\"https:\/\/files.atlas-scientific.com\/CE-Certificate.pdf\"\u003eCE Certificate\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul id=\"product-files-links\"\u003e\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e3D file\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul id=\"product-files-links\"\u003e\n\u003cli class=\"product-files-links-item\"\u003e\n\u003cimg class=\"attachment-full size-full\" src=\"https:\/\/atlas-scientific.com\/files\/autodesk-white.png\" alt=\"\" width=\"60\" height=\"60\" data-mce-src=\"https:\/\/atlas-scientific.com\/files\/autodesk-white.png\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Ezo-Complete.zip\" target=\"_blank\" data-mce-href=\"https:\/\/files.atlas-scientific.com\/Ezo-Complete.zip\"\u003eEZO-Complete - 3D model (*.step)\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Atlas Scientific","offers":[{"title":"Default Title","offer_id":49715494420763,"sku":"EZO-COM-DO","price":14799.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0676\/3325\/0587\/files\/DO-EZO-Complete-01.jpg?v=1733222176"}],"url":"https:\/\/mgsl.in\/collections\/dissolved-oxygen-products.oembed","provider":"MG Super Labs","version":"1.0","type":"link"}