{"title":"Conductivity Products","description":"Atlas Scientific conductivity probes, circuits, kits, and calibration solutions.","products":[{"product_id":"as-chem-ec-0-1","title":"Atlas Scientific Conductivity Calibration K 0.1 Set","description":"\u003cp\u003eHigh accuracy sensors require high accuracy calibration solutions.\u003c\/p\u003e\n\u003cp\u003eAtlas Scientific conductivity calibration solutions are made using a six-stage process to ensure the highest accuracy. If you need a certificate on analysis, just email \u003ca href=\"mailto:Support@Atlas-Scientific.com\" rel=\"noopener noreferrer\" target=\"_blank\"\u003esupport \u003c\/a\u003ewith the lot number and expiration date of your calibration solution.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"product-specs-table\" border=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e• For K 0.1 Calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e• 125ml (4oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e• Standardized against NIST-certified references\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e• 2 year shelf life at room temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e• This set includes 1 (84µS) and 1 (1,413µS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Atlas Scientific","offers":[{"title":"Default Title","offer_id":47400996831515,"sku":"AS-CHEM-EC-0.1","price":3149.0,"currency_code":"INR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0676\/3325\/0587\/products\/ec-low.png?v=1701982642"},{"product_id":"as-chem-ec-1-0","title":"Atlas Scientific Conductivity Calibration K 1.0 set","description":"\u003cp\u003eHigh accuracy sensors require high accuracy calibration solutions.\u003c\/p\u003e\n\u003cp\u003eAtlas Scientific conductivity calibration solutions are made using a six-stage process to ensure the highest accuracy. If you need a certificate on analysis, just email \u003ca href=\"mailto:Support@Atlas-Scientific.com\" rel=\"noopener noreferrer\" target=\"_blank\"\u003esupport \u003c\/a\u003ewith the lot number and expiration date of your calibration solution.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"product-specs-table\" border=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e• For K 1.0 Calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e• 125ml (4oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e• Standardized against NIST-certified references\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e• 2 year shelf life at room temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e• This set includes 1 (12,880µS) and 1 (80,000µS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Atlas Scientific","offers":[{"title":"Default Title","offer_id":47400996897051,"sku":"AS-CHEM-EC-1.0","price":2769.0,"currency_code":"INR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0676\/3325\/0587\/products\/ec-mid.png?v=1701982646"},{"product_id":"as-chem-ec-10","title":"Atlas Scientific Conductivity Calibration K 10 set","description":"\u003cp\u003eHigh accuracy sensors require high accuracy calibration solutions.\u003c\/p\u003e\n\u003cp\u003eAtlas Scientific conductivity calibration solutions are made using a six-stage process to ensure the highest accuracy. If you need a certificate on analysis, just email \u003ca href=\"mailto:Support@Atlas-Scientific.com\" rel=\"noopener noreferrer\" target=\"_blank\"\u003esupport \u003c\/a\u003ewith the lot number and expiration date of your calibration solution.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e• For K 10 Calibration\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• 125ml (4oz)\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Standardized against NIST-certified references\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• 2 year shelf life at room temperature\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• This set includes 1 (12,880µS) and 1 (150,000µS)\u003c\/span\u003e\u003c\/p\u003e","brand":"Atlas Scientific","offers":[{"title":"Default Title","offer_id":47400996929819,"sku":"AS-CHEM-EC-10","price":2529.0,"currency_code":"INR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0676\/3325\/0587\/products\/ec-high.png?v=1701982650"},{"product_id":"as-ec-kit-0-1","title":"Atlas Scientific Conductivity K 0.1 Kit","description":"\u003cp\u003e\u003cspan\u003eIf you are new to electrochemical sensing, knowing what components you need can get confusing. Let us help you. \u003c\/span\u003e\u003cspan\u003eThe Atlas Scientific K0.1 EZO-\u003c\/span\u003e\u003cspan\u003eConductivity Kit is perfect measuring water with a conductivity range from 0.07µs to 50,000µs. That means this kit is perfect for high purity water applications. And because the K0.1 kit can read well beyond the range of high purity water, you can trust that readings outside of the desired range will still be accurate. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"product-specs-table\" border=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e• 1 EZO™ Conductivity Circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e• 1 Conductivity Probe: 0.07 µS\/cm to 50,000 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e• 2 125ml (4oz) calibration solutions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eK 0.1 – This set includes 1 (84µS) and 1 (1,413µS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e• 1 Electrically Isolated EZO™ Carrier Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable class=\"product-specs-table\" style=\"height: 85px; width: 312px;\" border=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarrier Board dimensions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e56.2mm x 32mm (2.2″ x 1.2″)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight: 25 grams\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Atlas Scientific","offers":[{"title":"Default Title","offer_id":47400996962587,"sku":"AS-EC-KIT-0.1","price":29139.0,"currency_code":"INR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0676\/3325\/0587\/products\/Conductivity-Kit-K-0-1-01-2.jpg?v=1701982668"},{"product_id":"as-ec-kit-1-0","title":"Atlas Scientific Conductivity K 1.0 Kit","description":"\u003cdiv class=\"elementor-toggle-item\"\u003e\n\u003cdiv id=\"elementor-tab-title-6842\" class=\"elementor-tab-title elementor-active\" data-tab=\"2\"\u003e\n\u003cdiv class=\"elementor-toggle-item\"\u003e\n\u003cdiv id=\"elementor-tab-title-6841\" class=\"elementor-tab-title elementor-active\" data-tab=\"1\"\u003e\u003ca class=\"elementor-toggle-title\" tabindex=\"0\"\u003eDocuments \u0026amp; Downloads\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv id=\"elementor-tab-content-6841\" class=\"elementor-tab-content elementor-clearfix elementor-active\" data-tab=\"1\"\u003eDatasheets\n\u003cul id=\"product-files-links\"\u003e\n\u003cli class=\"product-files-links-item\"\u003e\n\u003cimg class=\"attachment-full size-full\" src=\"https:\/\/atlas-scientific.com\/files\/conductivity-black.png\" alt=\"\" width=\"60\" height=\"60\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/EC_EZO_Datasheet.pdf\" target=\"_blank\"\u003eEZO™ Conductivity Circuit Datasheet\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\n\u003cimg class=\"attachment-full size-full\" src=\"https:\/\/atlas-scientific.com\/files\/conductivity-black.png\" alt=\"\" width=\"60\" height=\"60\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/EC_K_1.0_probe.pdf\" target=\"_blank\"\u003eConductivity Probe K 1.0 Datasheet\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\n\u003cimg class=\"attachment-full size-full\" src=\"https:\/\/atlas-scientific.com\/files\/power-black.png\" alt=\"\" width=\"60\" height=\"60\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/electrically-isolated-ezo-carrier-board.pdf\" target=\"_blank\"\u003eElectrically Isolated EZO™ Carrier Board Datasheet\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\nDocuments\n\u003cul id=\"product-files-links\"\u003e\n\u003cli class=\"product-files-links-item\"\u003e\n\u003cimg class=\"attachment-full size-full\" src=\"https:\/\/atlas-scientific.com\/files\/conductivity-black.png\" alt=\"\" width=\"60\" height=\"60\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/conductivity_accuracy_graph.pdf\" target=\"_blank\"\u003eEZO™ Conductivity Accuracy Graph\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\n\u003cimg class=\"attachment-full size-full\" src=\"https:\/\/atlas-scientific.com\/files\/wiring-digram-black.png\" alt=\"\" width=\"60\" height=\"60\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/ezo-ec-wiringdiagram.pdf\" target=\"_blank\"\u003eWiring Diagram\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\n\u003cimg class=\"attachment-full size-full\" src=\"https:\/\/atlas-scientific.com\/files\/atlas-black.png\" alt=\"\" width=\"60\" height=\"60\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/connecting-probes-into-a-pipe.pdf\" target=\"_blank\"\u003eConnecting probes into a pipe\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\n\u003cimg class=\"attachment-full size-full\" src=\"https:\/\/atlas-scientific.com\/files\/atlas-black.png\" alt=\"\" width=\"60\" height=\"60\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/how-to-properly-cut-probe-cables.pdf\" target=\"_blank\"\u003eHow to properly cut your probe cable\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\n\u003cimg class=\"attachment-full size-full\" src=\"https:\/\/atlas-scientific.com\/files\/pdf-black.png\" alt=\"\" width=\"60\" height=\"60\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/RoHS-Certificate.pdf\" target=\"_blank\"\u003eRoHS Certificate\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\n\u003cimg class=\"attachment-full size-full\" src=\"https:\/\/atlas-scientific.com\/files\/pdf-black.png\" alt=\"\" width=\"60\" height=\"60\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/CE-Certificate.pdf\" target=\"_blank\"\u003eCE Certificate\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\n\u003cimg class=\"attachment-full size-full\" src=\"https:\/\/atlas-scientific.com\/files\/pdf-black.png\" alt=\"\" width=\"60\" height=\"60\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/csa-certificate.pdf\" target=\"_blank\"\u003eCSA Certificate\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\nDownloads\n\u003cul id=\"product-files-links\"\u003e\n\u003cli class=\"product-files-links-item\"\u003e\n\u003cimg class=\"attachment-full size-full\" src=\"https:\/\/atlas-scientific.com\/files\/download-black.png\" alt=\"\" width=\"60\" height=\"60\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/AtlasDesktop.zip\" target=\"_blank\"\u003eFREE Software - AtlasDesktop Monitoring Software\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\n\u003cimg class=\"attachment-full size-full\" src=\"https:\/\/atlas-scientific.com\/files\/pdf-black.png\" alt=\"\" width=\"60\" height=\"60\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Atlasdesktop-user-guide.pdf\" target=\"_blank\"\u003eAtlasDesktop Monitoring Software Users Guide\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\nBasic Sample Code\n\u003cul id=\"product-files-links\"\u003e\n\u003cli class=\"product-files-links-item\"\u003e\n\u003cimg class=\"attachment-full size-full\" src=\"https:\/\/atlas-scientific.com\/files\/arduino-black.png\" alt=\"\" width=\"60\" height=\"60\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Arduino-Uno-EC-sample-code.pdf\" target=\"_blank\"\u003eArduino Uno Sample Code\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\n\u003cimg class=\"attachment-full size-full\" src=\"https:\/\/atlas-scientific.com\/files\/arduino-black.png\" alt=\"\" width=\"60\" height=\"60\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Arduino-Mega-Giga-EC-Sample-Code.pdf\" target=\"_blank\"\u003eArduino Mega \/ Giga Sample Code\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\n\u003cimg class=\"attachment-full size-full\" src=\"https:\/\/atlas-scientific.com\/files\/arduino-black.png\" alt=\"\" width=\"60\" height=\"60\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Ardunio-I2C-EC-sample-code.pdf\" target=\"_blank\"\u003eArduino I2C Sample Code\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\n\u003cimg class=\"attachment-full size-full\" src=\"https:\/\/atlas-scientific.com\/files\/raspberry-pi-black.png\" alt=\"\" width=\"60\" height=\"60\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/pi_sample_code.pdf\" target=\"_blank\"\u003eRaspberry Pi Sample Code (UART, I2C, USB)\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n3D file\n\u003cul id=\"product-files-links\"\u003e\n\u003cli class=\"product-files-links-item\"\u003e\n\u003cimg class=\"attachment-full size-full\" src=\"https:\/\/atlas-scientific.com\/files\/autocad-black.png\" alt=\"\" width=\"60\" height=\"60\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/EC-EZO-footprint.zip\" target=\"_blank\"\u003eConductivity CAD Footprint File (*.dxf)\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\nLibrary\n\u003cul id=\"product-files-links\"\u003e\n\u003cli class=\"product-files-links-item\"\u003e\n\u003cimg class=\"attachment-full size-full\" src=\"https:\/\/atlas-scientific.com\/files\/git-hub-black.png\" alt=\"\" width=\"60\" height=\"60\"\u003e\u003ca href=\"https:\/\/github.com\/Atlas-Scientific\/Ezo_uart_lib\" target=\"_blank\"\u003eEZO UART Library\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\n\u003cimg class=\"attachment-full size-full\" src=\"https:\/\/atlas-scientific.com\/files\/git-hub-black.png\" alt=\"\" width=\"60\" height=\"60\"\u003e\u003ca href=\"https:\/\/github.com\/Atlas-Scientific\/Ezo_I2c_lib\" target=\"_blank\"\u003eEZO I2C Library\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul id=\"product-files-links\"\u003e\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"elementor-toggle-item\"\u003e\n\u003cdiv id=\"elementor-tab-title-6842\" class=\"elementor-tab-title elementor-active\" data-tab=\"2\"\u003e\u003ca class=\"elementor-toggle-title\" tabindex=\"0\"\u003eDescription\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv id=\"elementor-tab-content-6842\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"2\"\u003e\n\u003cp\u003e\u003cspan\u003eIf you are new to electrochemical sensing, knowing what components you need can get confusing. Let us help you. \u003c\/span\u003e\u003cspan\u003eThe Atlas Scientific K1 EZO-\u003c\/span\u003e\u003cspan\u003eConductivity Kit is perfect measuring water with a conductivity range from 10µs to 100,000µs. That means this kit is perfect for environmental monitoring, hydroponics, and both freshwater and saltwater aquariums.  \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"elementor-toggle-item\"\u003e\n\u003cdiv id=\"elementor-tab-title-6843\" class=\"elementor-tab-title elementor-active\" data-tab=\"3\"\u003e\u003ca class=\"elementor-toggle-title\" tabindex=\"0\"\u003eSpecifications\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv id=\"elementor-tab-content-6843\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"3\"\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable class=\"product-specs-table mceItemTable\" border=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e• 1x EZO™ Conductivity Circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e• 1x Conductivity Probe: 5 µS\/cm to 200,000 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e• 1x Electrically Isolated EZO™ Carrier Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e• 4x 20ml calibration solution pouches (2x 12,880µS and 2x 80,000µS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarrier Board dimensions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e56.2mm x 32mm (2.2″ x 1.2″)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight: 25 grams\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"elementor-toggle-item\"\u003e \u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Atlas Scientific","offers":[{"title":"Default Title","offer_id":47400997617947,"sku":"AS EC-KIT-1.0","price":29899.0,"currency_code":"INR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0676\/3325\/0587\/files\/EC-KIT-1.0-01.jpg?v=1779186615"},{"product_id":"as-ec-kit-10","title":"Atlas Scientific Conductivity K 10 Kit","description":"\u003cp\u003e\u003cspan\u003eIf you are new to electrochemical sensing, knowing what components you need can get confusing. Let us help you. \u003c\/span\u003e\u003cspan\u003eThe Atlas Scientific K10 EZO-\u003c\/span\u003e\u003cspan\u003eConductivity Kit is perfect measuring water with a conductivity range from 70µs to 500,000+µs. This kit is perfect for saltwater and chemical process monitoring.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"product-specs-table\" border=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e• 1 EZO™ Conductivity Circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e• 1 Conductivity Probe: 10 µS\/cm to 1S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e• 2 125ml (4oz) calibration solutions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eK 10 – This set includes 1 (12,880µS) and 1 (150,000µS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e• 1 Electrically Isolated EZO™ Carrier Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable class=\"product-specs-table\" style=\"height: 85px; width: 338px;\" border=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarrier Board dimensions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e56.2mm x 32mm (2.2″ x 1.2″)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight: 25 grams\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Atlas Scientific","offers":[{"title":"Default Title","offer_id":47400997650715,"sku":"AS-EC-KIT-10","price":26339.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0676\/3325\/0587\/products\/Conductivity-Kit-K-1-0-01-3_d274ef20-53dc-4f37-94bc-e7d94eeafeff.jpg?v=1701982724"},{"product_id":"as-chem-ec-205","title":"Atlas Scientific Conductivity Probe Cleaner","description":"\u003cp\u003e\u003cspan\u003eOver time Conductivity Probes can become dirty and covered in mineral deposits.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThis can change the basic electrical properties of the probe and cause inaccurate readings.\u003c\/p\u003e\n\u003cp\u003eCleaning the probe can be a bit tricky; you can’t simply scrub it with a brush without destroying the fragile platinum conductors inside the probe. Take care of your Conductivity Probe, if the probe is not well maintained how accurate will your readings be?\u003c\/p\u003e","brand":"Atlas Scientific","offers":[{"title":"Default Title","offer_id":47400997683483,"sku":"AS-CHEM-EC-205","price":1839.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0676\/3325\/0587\/products\/ec-probe-cleaner.png?v=1701982728"},{"product_id":"as-env-40-ec-k0-1","title":"Atlas Scientific Conductivity Probe K 0.1","description":"\u003cp\u003e\u003cspan\u003eThis Conductivity Probe can be \u003c\/span\u003e\u003cspan\u003efully submerged\u003c\/span\u003e\u003cspan\u003e in fresh water or salt water, up to the BNC connector \u003c\/span\u003e\u003cspan\u003eindefinitely.\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable style=\"height: 288px; width: 434px;\" border=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReads\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConductivity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.07 − 50,000 μS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/ – 2%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMale BNC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResponse time\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90% in 1s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax pressure\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3,447 kPa (500PSI)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax depth\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e343 meters (1,125 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature range °C\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 − 110 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable length\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e343 meters (1,125 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInternal temperature sensor\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTime before recalibration\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e~10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv id=\"spec-text\"\u003e\u003cstrong\u003eLife expectancy\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e~10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv id=\"spec-text\"\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/div\u003e","brand":"Atlas Scientific","offers":[{"title":"Default Title","offer_id":47400998207771,"sku":"AS ENV-40-EC-K0.1","price":20749.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0676\/3325\/0587\/products\/Conductivity-probe-K-0-1-01-optinal.jpg?v=1701982746"},{"product_id":"as-env-40-ec-k1-0","title":"Atlas Scientific Conductivity Probe K 1.0","description":"\u003cp\u003e\u003cspan\u003eThis Conductivity Probe can be \u003c\/span\u003e\u003cspan\u003efully submerged\u003c\/span\u003e\u003cspan\u003e in fresh water or salt water, up to the BNC connector \u003c\/span\u003e\u003cspan\u003eindefinitely.\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable border=\"0\" style=\"height: 321px; width: 477px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReads\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConductivity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 − 200,000 μS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/ – 2%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMale BNC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResponse time\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90% in 1s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax pressure\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3,447 kPa (500PSI)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax depth\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e343 meters (1,125 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature range °C\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 − 110 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable length\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInternal temperature sensor\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTime before recalibration\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e~10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLife expectancy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e~10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv id=\"spec-text\"\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/div\u003e","brand":"Atlas Scientific","offers":[{"title":"Default Title","offer_id":47400998535451,"sku":"AS-ENV-40-EC-K1.0","price":16319.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0676\/3325\/0587\/files\/ENV-40-EC-K1.webp?v=1736448624"},{"product_id":"as-env-40-ec-k10","title":"Atlas Scientific Conductivity Probe K 10","description":"\u003cp\u003e\u003cspan\u003eOver the years, we have tested an endless number of conductivity probe designs. Our research has shown us that not all conductivity probes are the same. Many lower-quality probes are susceptible to “fringe effect,” which makes the readings change when the probe is near an object. This effect makes it very difficult to take accurate readings. The Atlas Scientific line of conductivity probes has been designed to provide stable and precise readings free of fringe effect over a broad conductivity range. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eBecause conductivity probes don’t have any electrolyte that gets depleted, they only need to be calibrated during installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"product-specs-table\" border=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eReads\u003c\/td\u003e\n\u003ctd\u003eConductivity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e10 μS\/cm − 1 S\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e+\/ – 2%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse time\u003c\/td\u003e\n\u003ctd\u003e90% in 1s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature range °C\u003c\/td\u003e\n\u003ctd\u003e1 − 110 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax pressure\u003c\/td\u003e\n\u003ctd\u003e200 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax depth\u003c\/td\u003e\n\u003ctd\u003e60m (197 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector\u003c\/td\u003e\n\u003ctd\u003eMale SMA \/ Male BNC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable length\u003c\/td\u003e\n\u003ctd\u003e1 meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal temperature sensor\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTime before recalibration\u003c\/td\u003e\n\u003ctd\u003e~10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLife expectancy\u003c\/td\u003e\n\u003ctd\u003e~10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Atlas Scientific","offers":[{"title":"Default Title","offer_id":47400998600987,"sku":"AS-ENV-40-EC-K10","price":21329.0,"currency_code":"INR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0676\/3325\/0587\/products\/Conductivity-probe-K-1-0-01-optionalaXobfrPTkZMcY_0492ae30-3640-4b9a-a0d2-c6fd96f383df.jpg?v=1734979621"},{"product_id":"as-ec-oem","title":"Atlas Scientific Conductivity OEM Circuit","description":"\u003cdiv\u003e\n\u003ctable style=\"height: 285px; width: 466px;\" border=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReads\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConductivity\u003cbr\u003eTotal dissolved solids (ppm)\u003cbr\u003eSalinity = PSU (ppt) 0.00 − 42.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.07 − 500,000+ μS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/ – 2%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResponse time\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 reading every 640ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupported probes\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eK 0.01 – K 600 any brand\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCalibration\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 or 2 point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemp compensation\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData protocol\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSMBus\/I2C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDefault I2C address\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0x64\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating voltage\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.3V − 5V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv id=\"spec-text\"\u003e\u003cstrong\u003eData format\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003eASCII\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOEM Circuit Specs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e• Dimensions: 12mm x 11mm (0.47\" x 0.43\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv id=\"spec-text\"\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/div\u003e","brand":"Atlas Scientific","offers":[{"title":"Default Title","offer_id":47400998633755,"sku":"AS-EC-OEM","price":7479.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0676\/3325\/0587\/products\/ec-oem-coin.jpg?v=1701982813"},{"product_id":"as-ezo-ec","title":"Atlas Scientific EZO Conductivity Circuit","description":"\u003ctable style=\"height: 318px; width: 431px;\" border=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReads\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConductivity = μS\/cm\u003cbr\u003eTotal dissolved solids = ppm\u003cbr\u003eSalinity = PSU (ppt) 0.00 – 42.00\u003cbr\u003eSpecific gravity\u003cbr\u003e(sea water only) = 1.00 – 1.300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.07 − 500,000+ μS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/ – 2%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResponse time\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 reading per sec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupported probes\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eK 0.1 – K 10 any brand\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCalibration\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 or 3 point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemp. compensation\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData protocol\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUART \u0026amp; I2C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDefault I2C address\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 (0x64)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating voltage\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.3V − 5V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv id=\"spec-text\"\u003e\u003cstrong\u003eData format\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv id=\"spec-text2\"\u003eASCII\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cstrong\u003eCircuit dimensions\u003c\/strong\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd\u003e13.97mm x 20.16mm (0.55\" x 0.79\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv id=\"unit-info2\"\u003e\u003ciframe frameborder=\"0\" src=\"https:\/\/www.youtube.com\/embed\/-T8uzA6pHWQ?\u0026amp;loop=1;rel=0\u0026amp;controls=0\u0026amp;showinfo=0\u0026amp;playlist=-T8uzA6pHWQ\" width=\"454\" height=\"255\" allowfullscreen=\"allowfullscreen\"\u003e\u003c\/iframe\u003e\u003c\/div\u003e\n\u003cdiv id=\"spec-text\"\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/div\u003e","brand":"Atlas Scientific","offers":[{"title":"Default Title","offer_id":47400998797595,"sku":"AS-EZO-EC","price":7929.0,"currency_code":"INR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0676\/3325\/0587\/products\/ezo-ec.png?v=1701982859"},{"product_id":"as-kit-106e","title":"Atlas Scientific Industrial Conductivity Kit K 1.0","description":"\u003cdiv\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e• 1 IXIAN™ Conductivity Transmitter\u003cbr\u003e• 1 Industrial Conductivity Probe K 1.0\u003cbr\u003e• 3\/4″ NPT pipe thread on input and output side\u003cbr\u003e• 2 250ml (8oz) calibration solutions\u003cbr\u003eK 1.0 – This set includes 1 (1,413µS) and 1 (12,880µS)\u003cbr\u003eProbe Max Pressure: 1380 kPa (200 Psi)\u003cbr\u003eProbe Cable length: 10Ft\u003cbr\u003eProbe Weight: 354 grams\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"unit-info2\"\u003e \u003c\/div\u003e\n\u003cdiv id=\"unit-price2\"\u003e \u003c\/div\u003e","brand":"Atlas Scientific","offers":[{"title":"Default Title","offer_id":47400999026971,"sku":"AS-KIT-106E","price":75189.0,"currency_code":"INR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0676\/3325\/0587\/products\/img-1BnVvGELoQsb3Z.jpg?v=1701982872"},{"product_id":"as-env-50-ec-1-0","title":"Atlas Scientific Industrial Conductivity Probe K 1.0","description":"\u003cdiv\u003e\n\u003ctable style=\"height: 286px; width: 499px;\" border=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReads\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConductivity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 − 200,000μS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/ – 2%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTinned leads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResponse time\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90% in 1s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax pressure\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax depth\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60m (197 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature range °C\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 − 110 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable length\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 meters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePipe fitting\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\/4\" threaded NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInternal temperature sensor\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes (PT-1000)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTime before recalibration\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e~10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv id=\"spec-text\"\u003e\u003cstrong\u003eLife expectancy\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e~10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv id=\"unit-price2\"\u003eThis Industrial Conductivity Probe is meant for inline use.\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"spec-text\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv id=\"spec-text5\"\u003e\u003cimg src=\"https:\/\/www.atlas-scientific.com\/_images\/probe_images\/sub\/iec-submerge.png\" alt=\"\" width=\"455\" height=\"156\"\u003e\u003c\/div\u003e\n\u003cdiv id=\"unit-info2\"\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/Xhu2Ca8UlpQ?\u0026amp;loop=1;rel=0\u0026amp;controls=0\u0026amp;showinfo=0\u0026amp;playlist=Xhu2Ca8UlpQ\" width=\"454\" height=\"255\" frameborder=\"0\" allowfullscreen=\"\"\u003e\u003c\/iframe\u003e\u003c\/div\u003e\n\u003cdiv id=\"unit-price2\"\u003e\u003cbr\u003e\u003c\/div\u003e","brand":"Atlas Scientific","offers":[{"title":"Default Title","offer_id":47400999158043,"sku":"AS-ENV-50-EC-1.0","price":32059.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0676\/3325\/0587\/files\/97.jpg?v=1708940333"},{"product_id":"as-ixian-ec","title":"Atlas Scientific IXIAN Conductivity Transmitter","description":"\u003cp\u003eThose of us who work with PLCs clearly understand both the power and limitations of industrial computers. Modern low voltage elections and communication protocols aren’t easily compatible with PLCs. Fortunately, the Atlas Scientific IXIAN Conductivity transmitter makes it easy to get high accuracy conductivity readings on your PLC for less than half the price of comparable devices on the market today.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable border=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eReads\u003c\/td\u003e\n\u003ctd\u003eConductivity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0.07μS – 100,000μS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e+\/– 2%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003e1 or 2 point\u003cbr\u003e\u003cem\u003e(remotely though PLC or directly on board)\u003c\/em\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported probes\u003c\/td\u003e\n\u003ctd\u003eAny two lead conductivity probe\u003cbr\u003e\u003cem\u003e(K 0.01, K 0.1, K 1.0, K 10)\u003c\/em\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemp probe\u003c\/td\u003e\n\u003ctd\u003ePT-100 or PT-1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto temp compensation\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMount\u003c\/td\u003e\n\u003ctd\u003e35mm Din rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput\u003c\/td\u003e\n\u003ctd\u003e4 − 20mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating voltage\u003c\/td\u003e\n\u003ctd\u003e9VDC − 36VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrically isolated\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eDownloads:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul id=\"product-files-links\"\u003e\n\u003cli\u003e\n\u003cimg title=\"EZO™ Conductivity Circuit\" src=\"https:\/\/atlas-scientific.com\/files\/conductivity-black.png\" alt=\"EZO™ Conductivity Circuit\"\u003e \u003ca href=\"https:\/\/files.atlas-scientific.com\/EC_transmitter.pdf\" target=\"_blank\"\u003eIXIAN™ Conductivity Transmitter Datasheet\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cimg title=\"EZO™ pH Circuit\" src=\"https:\/\/atlas-scientific.com\/files\/pdf-black.png\" alt=\"EZO™ pH Circuit\"\u003e \u003ca href=\"https:\/\/files.atlas-scientific.com\/RoHS-Certificate.pdf\" target=\"_blank\"\u003eRoHS Certificate\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cimg title=\"EZO™ pH Circuit\" src=\"https:\/\/atlas-scientific.com\/files\/pdf-black.png\" alt=\"EZO™ pH Circuit\"\u003e \u003ca href=\"https:\/\/files.atlas-scientific.com\/CE-Certificate.pdf\" target=\"_blank\"\u003eCE Certifica\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Atlas Scientific","offers":[{"title":"Default Title","offer_id":47400999321883,"sku":"AS-IXIAN-EC","price":38469.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0676\/3325\/0587\/products\/ec_transmitter.png?v=1701982930"},{"product_id":"as-chem-iec-1-0","title":"Atlas Scientific Industrial Conductivity Calibration K 1.0 set","description":"\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eFor Industrial K 1.0 Calibration\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e125ml (4oz)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003eStandardized against NIST-certified references\u003c\/li\u003e\n\u003cli\u003e2 year shelf life at room temperature\u003c\/li\u003e\n\u003cli\u003eThis set includes 1 (1,413µS) and 1 (12,880µS)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Atlas Scientific","offers":[{"title":"Default Title","offer_id":47401002107163,"sku":"AS-Chem-IEC-1.0","price":2999.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0676\/3325\/0587\/products\/img-1Zo6evzIRkxOPe.jpg?v=1701983383"},{"product_id":"as-env-20-ec-k1-0","title":"Atlas Scientific Mini Conductivity Probe K 1.0","description":"\u003cp\u003e\u003cspan\u003eThis Mini Conductivity Probe can be \u003c\/span\u003e\u003cspan\u003efully submerged\u003c\/span\u003e\u003cspan\u003e in fresh water or salt water, up to the SMA connector \u003c\/span\u003e\u003cspan\u003eindefinitely.\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable style=\"height: 328px; width: 422px;\" border=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReads\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv id=\"spec-text\"\u003eConductivity\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv id=\"spec-text\"\u003e5 − 200,000 μS\/cm\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv id=\"spec-text\"\u003e+\/ – 2%\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv id=\"spec-text\"\u003eFemale SMA\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResponse time\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv id=\"spec-text\"\u003e90% in 1s\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax pressure\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv id=\"spec-text\"\u003e3,447 kPa (500PSI)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax depth\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv id=\"spec-text\"\u003e343 meters (1,125 ft)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature range °C\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv id=\"spec-text\"\u003e1 − 110 °C\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable length\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv id=\"spec-text\"\u003e89mm (3.5\")\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInternal temperature sensor\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv id=\"spec-text\"\u003eNo\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTime before recalibration\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv id=\"spec-text\"\u003e~10 years\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv id=\"spec-text\"\u003e\u003cstrong\u003eLife expectancy\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e~10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv id=\"spec-text\"\u003e \u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e","brand":"Atlas Scientific","offers":[{"title":"Default Title","offer_id":47401002336539,"sku":"AS-ENV-20-EC-K1.0","price":12819.0,"currency_code":"INR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0676\/3325\/0587\/products\/mini_ec_k1-0.png?v=1701983437"},{"product_id":"as-env-50-ec-0-1","title":"Atlas Scientific Industrial Conductivity Probe K 0.1","description":"\u003cp\u003e\u003cspan\u003eThe Atlas Scientific industrial conductive probe is designed for inline conductivity measurements. From industrial chemical processing to swimming pool monitoring, this probe can be used for just about anything. The 3\/4″ female NPT threading and integrated PT-1000 temperature probe makes for simple installation and operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eBecause conductivity probes don’t have any electrolyte that gets depleted, they only need to be calibrated during installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"product-specs-table\" style=\"height: 359px; width: 397px;\" border=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eReads\u003c\/td\u003e\n\u003ctd\u003eConductivity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0.07 − 50,000 μS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e+\/ – 2%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse time\u003c\/td\u003e\n\u003ctd\u003e90% in 1s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature range °C\u003c\/td\u003e\n\u003ctd\u003e0 − 110 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax pressure\u003c\/td\u003e\n\u003ctd\u003e200 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax depth\u003c\/td\u003e\n\u003ctd\u003e60m (197 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector\u003c\/td\u003e\n\u003ctd\u003eTinned leads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable length\u003c\/td\u003e\n\u003ctd\u003e3 meters (10′)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePipe fitting\u003c\/td\u003e\n\u003ctd\u003e3\/4″ threaded NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal temperature sensor\u003c\/td\u003e\n\u003ctd\u003eYes (PT-1000)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTime before recalibration\u003c\/td\u003e\n\u003ctd\u003e~10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLife expectancy\u003c\/td\u003e\n\u003ctd\u003e~10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Atlas Scientific","offers":[{"title":"Default Title","offer_id":47401003712795,"sku":"AS-ENV-50-EC-0.1","price":32059.0,"currency_code":"INR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0676\/3325\/0587\/products\/img-10ff5FkcfuNCTq.jpg?v=1701983730"},{"product_id":"as-chem-iec-0-1","title":"Atlas Scientific Industrial Conductivity Calibration K 0.1 Set","description":"\u003cp\u003eHigh accuracy sensors require high accuracy calibration solutions.\u003c\/p\u003e\n\u003cp\u003eAtlas Scientific conductivity calibration solutions are made using a six-stage process to ensure the highest accuracy. If you need a certificate of analysis, just email support with the lot number and expiration date of your calibration solution.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable style=\"height: 139px; width: 453px;\" border=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e• For Industrial K 0.1 Calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e• 250ml (8oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e• Standardized against NIST-certified references\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e• 2 year shelf life at room temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e• This set includes 1 (84µS) and 1 (1,413µS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Atlas Scientific","offers":[{"title":"Default Title","offer_id":47401004237083,"sku":"AS-chem-IEC-0.1","price":3999.0,"currency_code":"INR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0676\/3325\/0587\/products\/img-1pNhC5YLE6zscA.jpg?v=1701983904"},{"product_id":"as-kit-107e","title":"Industrial Conductivity Kit K 0.1","description":"\u003cp\u003eAre you working with a PLC and aren’t sure what parts are right for you? Let us help you. This is the Atlas Scientific, Industrial Conductivity kit. It comes with everything you need to take high accuracy, interference-free readings with a PLC. The industrial strength conductivity probe is ready for the job, whatever it may be. This probe doesn’t care, from batch process chemical production to wastewater treatment. You can use it for anything. The DIN rail mount and wide operating voltage makes it easy to install. The 4-20mA data output and display makes it easy to read. And the simple calibration protocol gets you up and running in no time.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable border=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e• 1 IXIAN™ Conductivity Transmitter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e• 1 Industrial Conductivity Probe K 0.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e• 3\/4″ NPT pipe thread on input and output side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e• 2 250ml (8oz) calibration solutions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eK 0.1 – This set includes 1 (84µS) and 1 (1,413µS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Max Pressure: 1380 kPa (200 Psi)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Cable length: 10Ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Weight: 354 grams\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Atlas Scientific","offers":[{"title":"Default Title","offer_id":47401005941019,"sku":"AS-KIT-107E","price":75189.0,"currency_code":"INR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0676\/3325\/0587\/products\/img-1NySgR2YA1C5nn.jpg?v=1701984107"},{"product_id":"as-m-ec-kit-1-0","title":"Atlas Scientific Mini Conductivity K 1.0 Kit","description":"\u003cp\u003eIf you are new to electrochemical sensing, knowing what components you need can get confusing. Let us help you. The Atlas Scientific Mini K1 EZO-Conductivity Kit is perfect measuring water with a conductivity range from 10µs to 100,000µs. That means this kit is perfect for environmental monitoring, hydroponics, and both freshwater and saltwater aquariums. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable border=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e• 1x EZO™ Conductivity Circuit\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e• 1x Mini Conductivity Probe: 5 µS\/cm to 200,000 µS\/cm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e• 1x 3 Meter SMA male to SMA female Extension Cable\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e• 1x Electrically Isolated EZO™ Carrier Board\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e• 2x 125ml (4oz) calibration solutions\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003eK 1.0 – This set includes 1 (12,880µS) and 1 (80,000µS)\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCarrier Board dimensions\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e56.2mm x 32mm (2.2″ x 1.2″)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWeight: 25 grams\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eDocuments:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul id=\"product-files-links\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/atlas-scientific.com\/files\/conductivity-black.png\" alt=\"\"\u003e \u003ca href=\"https:\/\/files.atlas-scientific.com\/EC_EZO_Datasheet.pdf\" target=\"_blank\"\u003eEZO™ Conductivity Circuit Datasheet\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/atlas-scientific.com\/files\/conductivity-black.png\" alt=\"\"\u003e \u003ca href=\"https:\/\/files.atlas-scientific.com\/Mini_EC_K_1.0_probe.pdf\" target=\"_blank\"\u003eMini Conductivity Probe K 1.0 Datasheet\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/atlas-scientific.com\/files\/conductivity-black.png\" alt=\"\"\u003e \u003ca href=\"https:\/\/files.atlas-scientific.com\/conductivity_accuracy_graph.pdf\" target=\"_blank\"\u003eEZO™ Conductivity Accuracy Graph\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/atlas-scientific.com\/files\/power-black.png\" alt=\"\"\u003e \u003ca href=\"https:\/\/files.atlas-scientific.com\/electrically-isolated-ezo-carrier-board.pdf\" target=\"_blank\"\u003eElectrically Isolated EZO™ Carrier Board Datasheet\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/atlas-scientific.com\/files\/wiring-digram-black.png\" alt=\"\"\u003e \u003ca href=\"https:\/\/files.atlas-scientific.com\/ezo-ec-wiringdiagram.pdf\" target=\"_blank\"\u003eWiring Diagram\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/atlas-scientific.com\/files\/arduino-black.png\" alt=\"\"\u003e \u003ca href=\"https:\/\/files.atlas-scientific.com\/Arduino-Uno-EC-sample-code.pdf\" target=\"_blank\"\u003eArduino Uno Sample Code\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/atlas-scientific.com\/files\/arduino-black.png\" alt=\"\"\u003e \u003ca href=\"https:\/\/files.atlas-scientific.com\/Arduino-Mega-EC-Sample-Code.pdf\" target=\"_blank\"\u003eArduino Mega Sample Code\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/atlas-scientific.com\/files\/arduino-black.png\" alt=\"\"\u003e \u003ca href=\"https:\/\/files.atlas-scientific.com\/Ardunio-I2C-EC-sample-code.pdf\" target=\"_blank\"\u003eArduino I2C Sample Code\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/atlas-scientific.com\/files\/raspberry-pi-black.png\" alt=\"\"\u003e \u003ca href=\"https:\/\/files.atlas-scientific.com\/pi_sample_code.pdf\" target=\"_blank\"\u003eRaspberry Pi Sample Code (UART, I2C, USB)\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/atlas-scientific.com\/files\/atlas-black.png\" alt=\"\"\u003e \u003ca href=\"https:\/\/files.atlas-scientific.com\/connecting-probes-into-a-pipe.pdf\" target=\"_blank\"\u003eConnecting probes into a pipe\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/atlas-scientific.com\/files\/atlas-black.png\" alt=\"\"\u003e \u003ca href=\"https:\/\/files.atlas-scientific.com\/how-to-properly-cut-probe-cables.pdf\" target=\"_blank\"\u003eHow to properly cut your probe cable\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/atlas-scientific.com\/files\/autocad-black.png\" alt=\"\"\u003e \u003ca href=\"https:\/\/files.atlas-scientific.com\/EC-EZO-footprint.zip\" target=\"_blank\"\u003eConductivity CAD Footprint File (*.dxf)\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/atlas-scientific.com\/files\/thingaverse-black.png\" alt=\"\"\u003e \u003ca href=\"https:\/\/www.thingiverse.com\/thing:437623\" target=\"_blank\"\u003eDual Probe Holder - 3D printer file\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Atlas Scientific","offers":[{"title":"Default Title","offer_id":47401006858523,"sku":"AS-M-EC-KIT-1.0","price":23309.0,"currency_code":"INR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0676\/3325\/0587\/products\/Mini-Conductivity-Kit-K-1-0-01.jpg?v=1701984367"},{"product_id":"conductivity-calibration-k-1-0-set-4-pouches","title":"Conductivity Calibration K 1.0 Set (4 pouches)","description":"\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"elementor-toggle-item\"\u003e\n\u003cdiv id=\"elementor-tab-title-6841\" class=\"elementor-tab-title elementor-active\" data-tab=\"1\"\u003e\u003ca class=\"elementor-toggle-title\" tabindex=\"0\"\u003eDocuments \u0026amp; Downloads\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv id=\"elementor-tab-content-6841\" class=\"elementor-tab-content elementor-clearfix elementor-active\" data-tab=\"1\"\u003e\n\u003cul id=\"product-files-links\"\u003e\n\u003cli class=\"product-files-links-item\"\u003e\n\u003cimg class=\"attachment-full size-full\" src=\"https:\/\/atlas-scientific.com\/files\/pdf-black.png\" alt=\"\" width=\"60\" height=\"60\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Conductivity-k1.0-SDS.pdf\" target=\"_blank\"\u003eConductivity Calibration K 1.0 Set SDS\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"elementor-toggle-item\"\u003e\n\u003cdiv id=\"elementor-tab-title-6842\" class=\"elementor-tab-title elementor-active\" data-tab=\"2\"\u003e\u003ca class=\"elementor-toggle-title\" tabindex=\"0\"\u003eDescription\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv id=\"elementor-tab-content-6842\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"2\"\u003e\n\u003cp\u003eHigh accuracy sensors require high accuracy calibration solutions.\u003c\/p\u003e\n\u003cp\u003eAtlas Scientific conductivity calibration solutions are made using a six-stage process to ensure the highest accuracy. If you need a certificate of analysis, just email \u003ca href=\"mailto:Support@Atlas-Scientific.com\" rel=\"noopener noreferrer\" target=\"_blank\"\u003esupport \u003c\/a\u003ewith the lot number and expiration date of your calibration solution.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"elementor-toggle-item\"\u003e\n\u003cdiv id=\"elementor-tab-title-6843\" class=\"elementor-tab-title elementor-active\" data-tab=\"3\"\u003e\u003ca class=\"elementor-toggle-title\" tabindex=\"0\"\u003eSpecifications\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv id=\"elementor-tab-content-6843\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"3\"\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable class=\"product-specs-table mceItemTable\" border=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e• 20ml each pouch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e• For K 1.0 Calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e• 2x (12,880µS) and 2x (80,000µS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e• 2 year shelf life at room temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e• Standardized against NIST-certified references\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Atlas Scientific","offers":[{"title":"Default Title","offer_id":50038180217115,"sku":"AS EC-K1.0","price":2079.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0676\/3325\/0587\/files\/ASEC-K1.webp?v=1741775126"}],"url":"https:\/\/mgsl.in\/collections\/conductivity-products.oembed","provider":"MG Super Labs","version":"1.0","type":"link"}